Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
PXI 4 x Changeover Switch 1GHz, 75 SMB
40-710-754
Model 40-710 RF switching card has a bank of 4 individual high performance RF changeover switches (50 or 75 Ohm, Bi-directional) with very low insertion loss, suitable for handling signals up to 2.5GHz. Applications include aerial switching, routing high frequency signals into oscilloscopes and analysers.Available with a choice of connectors: SMA, SMB and Siemens 1.0/2.3 versions. BNC versions are also available with reduced bandwidth and 2 PXI slot occupancy.
-
product
VLF Receiver
T-Vlf
The VLF receiver is specially designed for high productivity surveys, in ground water and mining exploration. No orientation of the operator with respect to the direction of the transmitter is required since three magnetic sensors measure the components of the VLF field. Tilt or horizontality of the sensor unit is neither required since two inclinometers correct for tilted position.
-
product
VLF Electromagnetics
VLF surveying relies on radio signals that are broadcast from navigation stations around the world. The principle is that these signals are deflected in certain ways when they pass through conductive ore or water-filled vertical-to-sub-vertial fractures in the earth. By monitoring these deflections, the position and, potentially, size of the target can be determined.
-
product
VLF test system
BAUR PHG 80 portable
BAUR Prüf- und Messtechnik GmbH
Portable, high performance test generator with VLF truesinus technology. The BAUR PHG 70/80 portable VLF test systems are used for cable and cable sheath testing of medium-voltage cables of up to 50 kV and electrical equipment.* 3 voltage shapes in one device: VLF truesinus, VLF square wave and DC voltage* For medium-voltage cables of up to 50 kV operating voltage* Cable testing, fault conditioning, cable sheath testing
-
product
VLF Test System
BAUR PHG 70 portable
BAUR Prüf- und Messtechnik GmbH
Portable, high performance test generator with VLF truesinus technology. The BAUR PHG 70/80 portable VLF test systems are used for cable and cable sheath testing of medium-voltage cables of up to 50 kV and electrical equipment.* 3 voltage shapes in one device: VLF truesinus, VLF square wave and DC voltage* For medium-voltage cables of up to 50 kV operating voltage* Cable testing, fault conditioning, cable sheath testing
-
product
VLF Insulation Testing
VLF testing uses very low frequencies as part of an AC cable maintenance routine. VLF testers are smaller and more practical than AC testers but output the same amount of power as a 50 Hz mains device. This combination of size and power makes Very Low Frequency cable testing perfect for testing longer sections of cable and apparatus
-
product
VLF Voltage Generators
Fivestar HV Testing Equipment Co., Ltd.
VLF hipot is an AC output tester with an output frequency of 0.1 Hz or lower rather than 50/60 Hz. Although the frequency is very low, it is an alternating current with polarity reversals every half cycle.
-
product
VLF Diagnostics System
PHG 80 TD
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR PHG 80 TD. The combination of the PHG 80 programmable test generator with the BAUR dissipation factor measurement system produces the cable testing and diagnostics system PHG TD. It is operated via PC control. Dissipation factor measurement and diagnostic testing sequences can be programmed in the menu, after which the dissipation factor measured values are automatically determined in various voltage steps and a final evaluation is conducted.* Biggest dynamic range of tan delta measured values from 1 to 10-4 with a cable capacitance >10 nF to 20 uF* High resolution +/- 1x10-5 applicable even in new PE/XLPE cables* Insensitive against interferences due to complete mains separation* Lowest time required for assessing a medium-voltage cable (3-phase approx. 1 hour)
-
product
VLF Diagnostics System
PHG 70 TD
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR PHG 70 TD. The combination of the PHG 70 programmable test generator with the BAUR dissipation factor measurement system produces the cable testing and diagnostics system PHG TD. It is operated via PC control. Dissipation factor measurement and diagnostic testing sequences can be programmed in the menu, after which the dissipation factor measured values are automatically determined in various voltage steps and a final evaluation is conducted.* Biggest dynamic range of tan delta measured values from 1 to 10-4 with a cable capacitance >10 nF to 20 uF* High resolution +/- 1x10-5 applicable even in new PE/XLPE cables* Insensitive against interferences due to complete mains separation* Lowest time required for assessing a medium-voltage cable (3-phase approx. 1 hour)
-
product
VLF Insulation Testing
Weshine Electric Manufacturing Co., Ltd
1. The current, voltage and waveform data are directly obtained from the high voltage side, so the data is accurate.2. It has over-voltage protection function. When the output exceeds the set voltage limit, the instrument will stop for protection, and the action time is less than 20ms.3. It has over-current protection function: it is designed as high-voltage and low-voltage dual protection, and the high-voltage side can carry out accurate shutdown protection according to the set value; when the current on the low-voltage side exceeds the rated current, it will carry out shutdown protection, and the action time is less than 20ms.
-
product
VLF Testing and Diagnostics System
PHG 70 TD/PD
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR PHG 70 TD/PD. With the PHG TD/PD, you get a multifunctional cable testing and diagnostics system that was specially designed and developed for medium-voltage networks. The PHG TD/PD system is also the only cable testing and diagnostics system that gives a comprehensive overview of the quality and ageing condition of the test sample. The diagnostic methods TD and PD are mutually complementary, because on one hand you can detect the complete condition and on the other hand locate * individual faults in the operating resources.* High performance VLF truesinus testing device (3 kW) with regulated output voltageCompact, enclosed design in 19" format* Variable installation option with separate control and voltage unit* Variable connection options to cable stations of different models
-
product
VLF Testing and Diagnostics System
PHG 80 TD/PD
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR PHG 80 TD/PD. With the PHG TD/PD, you get a multifunctional cable testing and diagnostics system that was specially designed and developed for medium-voltage networks. The PHG TD/PD system is also the only cable testing and diagnostics system that gives a comprehensive overview of the quality and ageing condition of the test sample. The diagnostic methods TD and PD are mutually complementary, because on one hand you can detect the complete condition and on the other hand locate individual faults in the operating resources.* High performance VLF truesinus testing device (3 kW) with regulated output voltage* Compact, enclosed design in 19" format* Variable installation option with separate control and voltage unit* Variable connection options to cable stations of different models
-
product
VLF Hipot Test Set
HTDP-H
Wuhan Huatian Electric Power Automation Co., Ltd.
Suitable for voltage test items of electrical equipment with large insulation equivalent capacitance.
-
product
VLF Testing and Diagnostics Unit
Viola TD
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR viola TD. The portable and high performance high-voltage testing and diagnostics device is available in two different configurations:viola: Used for cable and cable sheath testing of electrical equipment and medium-voltage cables up to 35 kV. Another function is insulation testing on electrical equipment. viola TD: Expands the functional scope of viola with the tan delta diagnostics and Monitored Withstand Test (MWT) that combines the cable testing and dissipation factor measurement. This allows for an accurate and comprehensive assessment of the cable condition.* Cable testing and dissiation factor diagnostics in one device* High performance and compact* Easy and quick test setup* Automatic testing and diagnostic sequences
-
product
VLF Testing and Diagnostics Unit
Frida TD
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR frida TD. The portable and high performance high-voltage testing and diagnostics device is available in two different configurations: frida: Used for cable and cable sheath testing of medium-voltage cables and electrical equipment up to 20 kV. Another function is insulation testing on electrical equipment.frida TD: Expands the functional scope of frida with the tan delta diagnostics and Monitored Withstand Test (MWT) that combines the cable testing and dissipation factor measurement. This allows for an accurate and comprehensive assessment of the cable condition.* Cable testing and dissipation factor diagnostics in one device* Easy and quick test setup* Automatic testing and diagnostic sequences* Compact dimensions and lightweight
-
product
VLF Testing and Diagnostics Unit
Frida
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR frida. The portable and powerful high-voltage testing and diagnostics device is used for cable and cable sheath testing of medium-voltage cables up to 20 kV and electrical equipment. Another function is insulation testing on electrical equipment.* Precise and non-destructive determination of the cable condition* Easy and quick test setup* Automatic testing and diagnostic sequences* Compact dimensions and lightweight
-
product
Portable High-Voltage VLF Test System
VLF-60
The system is designed for VLF (0.1 Hz) withstand testing of cross-linked polyethylene (XLPE) insulated cables.Integrated Tan Delta (tan δ) measurement module allows to evaluate the general condition of cable insulation according to IEEE 400.2-2013 international standard.
-
product
KPG 24kV VLF Test Set
Kilovolt Prueftechnik Chemnitz GmbH
The portable cable test set KPG 24kV VLF is used for testing of medium voltage cables in accordance to the standards IEC 60502-2, CENELEC HD 620 & 621, DIN VDE 0276/620 & 621 and IEEE 400.Test is carried out with a low strain practice with VLF (very low frequency) test voltage of preferably 0.1Hz.VLF testing enables detection of damages of insulation within shortest test time.
-
product
Metal Detector
VLF
The VLF Metal Detector will help you get started finding your treasure, without spending a fortune to get it.
-
product
Conventional Power Supply Design with Simple Analog Controls
VLF Series
VLF hipots perform voltage withstand tests and provide the voltage source for diagnostic cable testing. There is no better method for verifying the AC integrity of a cable than applying VLF AC voltage. Tan delta and partial discharge measurement accessories are frequently purchased along with VLF equipment to extend their capabilities.
-
product
AC Hipot Testers
VLF
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Programmable micro-controller• Advanced digital frequency technology• Built-in printer• Portable• AC HIPOT testing of cables and electrical apparatus is now easier than before• UDEY VLF testers are suitable for testing cables, transformers, switchgear, rotating machinery, & other electrical apparatus.
-
product
Fully Programmable Digital Design with Wireless Remote Control
VLF E Series
The VLF E Series uses a state-of-the-art, switching power supply design with wireless computer controls. Equipped with HVI’s E-Link software, the E Series stands among the most advanced cable testing systems available. Our customers praise its flexible data capture and reporting capabilities, full remote operation via XBee wireless technology, and seamless tan delta testing with HVI’s TD units.
-
product
Tan Delta Test System
Diagnostic test that indicates the degree of cable insulation degradation. Rather than using only a VLF instrument to perform a go/no-go proof test, the Tan Delta, used in conjunction with a VLF hipot, permits the user to grade the deterioration level of many cables in order to prioritize replacement, rejuvenation, or to determine what additional tests may be useful.
-
product
Partial Discharge and Tan Delta
PDIX Series
PDIX is a combined partial discharge and tan delta cable diagnostic testing system. By combining HVI’s VLF products with PDIX products, users can perform VLF AC withstand, partial discharge detection, and tan delta measurement on medium and high voltage cables, rotating machinery, and other apparatus with one integrated package fully supported by HVI & PDIX.
-
product
Frequency Counters
Handheld and bench-top frequency counters up to 6GHz Universal counters with VLF capability and pulse measurement and totalizing in addition to frequency/period.
-
product
RFI Detector Meter
MFJ-805
Use this ultra-sensitive pocket-sized RFI Detector to track down and eliminates RFI caused by radiating cables and wires. Usable from VLF to VHF. Gain adjustable over 50dB range.
-
product
Hipot Test Set
KVLF VLF
KV Hipot Power Test Equipment Co.,Ltd
Voltage withstand testing is an essential electric test for electric equipment to determine the effective of insulation .
-
product
3-AXIS DIGITAL AC GAUSSMETER: 1-200 kHz
IDR-200
Integrity Design and Reseach Corp.
Typical Applications include checking the frequencies and magnetic fields (BW: 1 kHz -200 kHz) produced by equipments such as computer monitors, television sets, video display terminals, induction heaters, industrial, Radar, scientific/medical equipment, walk-through/hand-held detectors and ground wave energy network; etc. For more information about VLF magnetic fields and the VLF gaussmeter , see the paper titled "Very-low-frequency electromagnetic field detector with data acquisition," IEEE Trans. Instrum. Meas.,vol. 58, no. 1, pp. 129-140, Dec. 2008. by S. Hanna.
-
product
VLF/DC Hipots
HVA28TD
The smallest VLF /DC unit on the market now includes an integrated Tan Delta measurement system to perform advanced electrical insulation diagnostics. For example, this can be extremely useful when performing advanced diagnostics on cable systems as it provides valuable information as to the condition of the cable insulation and shield.
-
product
Thumpers and Cable Fault Location
Cable testing can be broken down to different steps of the process, starting with a time domain reflectometer test to look for an incident signal on the line or, in some high resistance situations, VLF testing. These tests will identify a fault, allowing you to move on to pre-locating it. In some low resistance faults this will occur alongside the identification via the TDR.
-
product
Cable Diagnostic Tools
For non-destructive diagnostic testing to determine the quality of a cable’s insulation with minimal risk of failure, HVI recommends tan delta and partial discharge testing for valuable diagnostic data about cable insulation integrity. Both use a VLF source to perform elevated voltage, off-line testing. Tan delta testing measures insulation health, while PD identifies specific problem areas and assesses their severity.