Thermocouple Simulators
-
product
PXI Millivolt Thermocouple Simulators
Series 41-760
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channelseach channel providing a low-voltage output across two connector pins capable of providing 20mV with 0.7V resolution, 50mV with 1.7V resolution and 100mV with 3.3V resolution, covering most thermocouple types. These thermocouple simulators use two wire outputs with a remote output reference sense to ensure the modules deliver accurate low-level voltages, even if the system has common mode voltages present. In addition, each simulation channel is also able to provide an open circuit setting to simulate faulty wiring connections to a sensor.
-
product
PXI Thermocouple Simulators
Our PXI Millivolt Thermocouple Simulator modules provide 32, 24, 16 or 8 channels of accurate low sources. They are ideal for the simulation of thermocouples and can be used for sensor emulation in ECU testing. The channels can be operated with one of three voltage ranges covering most thermocouple types. We can also supply connection solutions allowing the easy integration of the Thermocouple Simulator into your test system.
-
product
PXI Isolated Millivolt Thermocouple Simulator - 24 Channel
41-761-002
The 41-761-002 is a low voltage 24-channel output module ideal for simulating theoperation of a thermocouple, also available with 32, 16 or 8 channels. Each channel of the 41-761 provides a low voltage output across two connector pins capable of providing ±20mV with 0.7μV resolution, ±50mV with 1.7μV resolution and ±100mV with 3.3μV resolution, covering most thermocouple types.
-
product
PXI Millivolt Thermocouple Simulator Module - 8 Channel
41-760-004
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 26 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types.
-
product
Thermocouple Calibrators
Practical Instrument Electronics, Inc.
PIE has a thermocouple calibrator to fit your needs from the PIE 520B single type thermocouple simulator to the advanced troubleshooting capabilities of the PIE 422Plus. Have you had issues in the past where your thermocouple calibrator wouldn’t work with some of the instruments in your plant? Our thermocouple calibrators are guaranteed to be compatible with all process thermocouple inputs including all brands of smart temperature transmitters, PLC input cards, DCS systems and multichannel recorders.
-
product
PXI Millivolt Thermocouple Simulator Module - 24 Channel
41-760-002
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types.
-
product
PXI Isolated Millivolt Thermocouple Simulator - 32 Channel
41-761-001
The 41-761-001 is a low voltage 32-channel output module ideal for simulating theoperation of a thermocouple, also available with 24, 16 or 8 channels. Each channel of the 41-761 provides a low voltage output across two connector pins capable of providing ±20mV with 0.7μV resolution, ±50mV with 1.7μV resolution and ±100mV with 3.3μV resolution, covering most thermocouple types.
-
product
Calibration Cable, 78-pin D-type, Thermocouple Simulator Modules
40-975-078-1m
This cable assembly is specifically designed to connect to the 78-Pin D-Type port on the front panel of Pickering Interfaces Thermocouple Simulator Modules 41-760 and 41-761 enabling calibration via an external DMM.
-
product
PXI Isolated Millivolt Thermocouple Simulator - 8 Channel
41-761-004
The use of two wire outputs and isolation from ground ensures that the 41-761 can be used to accurately simulate low voltages even in the presence of common mode voltages in the system. Each Vcold connection is independent permitting the 41-761 to be connected to multiple cold junctions.
-
product
Thermocouple Simulator Module for SLSC
Bloomy’s 8-Channel Thermocouple Simulator Module provides eight channels of galvanically-isolated thermocouple simulation and simulates types E, J, K, M, N, and T thermocouples. High-precision digital-to-analog converters which are isolated from each other and from system power provide sub-microvolt resolution and accuracy. Built-in switching provides open-circuit faults as well as switching to system calibration resources.
-
product
Engine Speed Control and Measurement (Test Set A)
MS 1100
*Checks the parameters such as current, voltage, speed, and turbine gas temperature of 804E and 811 engines Portable instrument*Testing of Automatic engine control system and after burner control system*Simulates the temperature signal derived from the engine TGT (Temperature Gas Turbine) thermocouples*Simulates the speed signal, NL (low pressure shaft speed signal) drive from the L.P shaft Probe*Indicates the current signal to the FCU solenoid derived from the engine control amplifier*Measure the TGT and NL simulated signal at static position*Measure the signal produced by the engine TGT thermocouples*Measure the NL signal produced by the LP shaft*Measure the NH (High-pressure shaft speed) signal produced by HP shaft*Indicates the solenoid current, produced by the engine control amplifier*Indicates the solenoid voltage, produced by the engine control amplifier*Used to test engine in both static and dynamic states
-
product
LXI And LXI/USB Modular Chassis
Our LXI modular chassis are available in 7 and 18-slot and our LXI/USB modular chassis are available in 2, 4 and 6-slot and support over 1,000 of our PXI modules. The PXI modules supported range from: PXI general purpose relays, matrices, multiplexers and RF switches to special PXI switching functions such as fault/signal insertion. Also supported are a selection of simulation modules such as programmable resistors, digital I/O, power supplies, thermocouple simulators, function generator, battery simulators and attenuators. This gives you enormous flexibility to define a switching or T&M system to exactly match your needs.
-
product
PXI Isolated Millivolt Thermocouple Simulator - 16 Channel
41-761-003
The 41-761-003 is a low voltage 16-channel output module ideal for simulating theoperation of a thermocouple, also available with 32, 24 or 8 channels. Each channel of the 41-761 provides a low voltage output across two connector pins capable of providing ±20mV with 0.7μV resolution, ±50mV with 1.7μV resolution and ±100mV with 3.3μV resolution, covering most thermocouple types.
-
product
Compensation Block for Thermocouple Simulator Modules
40-965-912
The Compensation Block is a accessory specifically designed for the 41-760 and 41-761 Millivolt Thermocouple Simulator modules. This block will give the user the temperature of the front panel junction of the module to cabling. This data can then be combined with other factors, temperature on the other end of the cable for example, to compensate the thermocouple hence increase the accuracy.
-
product
PXI Simulation Modules For Sensor Simulation
PXI simulation solutions for sensor simulation, including PXI Programmable Resistors—ideal for the simulation of resistive sensors and PXI Thermocouple Simulators—these provide multiple low-voltage sources ideal for simulating the operation of a thermocouple. Take a look below for all of our PXI Simulation Solutions, we also offer some of these in PCI format as well . All of our PXI simulation cards are supplied with comprehensive software drivers for Windows® XP/Vista/7/8, Lab Windows / CVI and LabView. The Pickering IVI drivers also fully support National Instruments' Switch Executive.
-
product
16-Channel VME Analog Output/Thermocouple Simulator Module
V470
The V470 is a 6U VME module that provides sixteen independent, isolated analog outputs that may be user-programmed to operate as voltage outputs or thermocouple simulators. Users may write temperature or voltage values at VMEbus speed, and the microprocessor will transparently do all necessary calculations and update the channel electronics.
-
product
PXI Millivolt Thermocouple Simulator Module - 32 Channel
41-760-001
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types.
-
product
PXI Millivolt Thermocouple Simulator Module - 16 Channel
41-760-003
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types.
-
product
E-Type Thermocouple, 32°F to 900°F Temperature Sensor
745690-E001
E-Type Thermocouple, 32°F to 900°F Temperature Sensor - The E-Type Thermocouple works with NI measurement devices and software to help you acquire temperature data within a measurement system. You can use LabVIEW or FlexLogger software and NI-DAQmx driver software to configure measurements and predefined scaling coefficients for the E-Type Thermocouple and acquire synchronized temperature data in units of degrees. The E-Type Thermocouple is available in various lengths and configurations including field-cuttable, ready-made sensors, and thermocouple wire extensions with a -20°F to 221°F temperature range.
-
product
Single Function MIL-STD-1553 Test & Simulation PCIe Card
ASE1553M-x
Single Function MIL-STD-1553 Test and Simulation module for PCIe with 1, 2 or 4 dual redundant streams.
-
product
Thermocouple, Contact, ITA, Chromel, Type K (°C)
610113133
Primary mating contact 610131131.Thermocouple contacts are manufactured from chromel or alumel alloys and color-coded for easy identification. Contacts are crimp terminated and easily inserted into the connector module. They can be readily removed from the connector module using a special removal tool.
-
product
PXI RTD Simulator Module 12-Channel PT1000
40-262-202
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
product
Thermocouple, ITA, 36", 24 AWG Thermocouple Wire K Type, Single Ended (3 Amps)
7-409803000-036
Thermocouple, ITA, 24 AWG Thermocouple Wire K Type (3 Amps), Twisted Pair, Single Ended
-
product
PXI RTD Simulator Module 6-Channel PT100
40-262-101
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
product
4, 8, 16 And 32 Channels ARINC429 Test & Simulation Module CompactPCI/PXI (3U)
ACXX429-3U-x
The ACXX429-3U-x is a functional replacement formodel ACX429-3U-x.
-
product
PXI RTD Simulator Module, 16 Channel, PT1000
40-263-203
The 40-263-203 is a 16-channel PT1000 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
product
Solar Array Simulator DC Module, 130V, 5A, 600W
E4362A
The Keysight E4362A is a 600W solar array simulator DC power module that simulates the output characteristics of a solar array. The E4362A is primarily a current source with very low output capacitance. It offers fast I-V curve changes allowing you to accurately simulate the output of different solar arrays under various environmental conditions (ex. temperature, age, eclipse, spin etc.). The E4360 gives you the flexibility to operate it in two ways:
-
product
Photovoltaic Array Simulator
PV8900 Series
Keysight’s photovoltaic (PV) simulator includes the hardware and software to test a single maximum power point tracking (MPPT) inverter accurately. Test PV voltages up to 2000 V and 60 A with a single supply. DG9000 Series software licenses are available to test string inverter with 4-, 8-, or 12-MPPT channels. Most string inverter solutions test one MPPT channel at a time — leading to test inaccuracies. Keysight's DG9000 advanced PV inverter software can test up to 12 MPPT channels simultaneously.
-
product
PXI RTD Simulator Module, 24 Channel, PT100
40-263-001
The 40-263-001 is a 24-channel PT100 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
product
Single Stream STANAG3910 Electrical Test & Simulation Module For 3U PXI Express/Compact PCI Express
ACE3910-3U-1-EN
Single Stream STANAG3910 Test and Simulation module – Rafale – for PXI Express/Compact PXI Express with 1 dual redundant HS/LS channel and onboard Electrical Front End (EFE).





























