Platinum
See Also: Precious Metal, Gold, Platinum RTD
-
product
Cryogenic Temperature Sensors
Platinum
PT-100 platinum resistance thermometers (PRTs) serve an important role in both cryogenic research and industrial cryogenics applications.
-
product
Larger Size Chambers
Platinum
The ESPEC Platinum series are top quality temperature/humidity chambers in larger sizes for temperature cycling of 2 to 15°C per minute. High performance, reliable Scroll compressors(most units). One adjustable shelf with heavy-duty support rails. Non-metallic thermal breaks at doorframe and cable ports to eliminate exterior frosting or hot spots
-
product
Environmental Test Chamber
The chamber is produced by SUS304 Steel, the temperature keeping material is produced by Polyurethane hard foam and ultra-fine fibre glass, the doorframe heat insulated by Double high temperature aging silicone rubber door sealing strip.The temperature controller is used by Korean TEMI display in English/Chinese and German Siemens PLC, it can be communicated to PC via RS-232. The temperature accuracy is 0.1 and humidity is 0.1%R.HThe temperature sensor is platinum PT100 Ohms/MV resistor
-
product
Multi-Function Recorder
Platinum 2.5K
For all types of power system events, the Platinum 2.5K Multi-Function Recorder provides all the information you need to capture the complete picture. This comprehensive fault recorder simultaneously performs transient, sequence of events and disturbance recordings, phasor measurements and power quality analysis. All of these functions are performed at the highest level so it will meet your needs of today and the future. In a deregulated environment, the Platinum 2.5K is the best tool to provide the necessary data to increase revenues and retain your customer.
-
product
Tracking Index Test Apparatus
CX-L19
Shenzhen Chuangxin Instruments Co., Ltd.
It applied with rectangle size of platinum electrode, each electrode can force to the sample is 1.0±0.05N. Electrode Distance: 4.0mm±0.01mm, included angle: 60°±5°. Electrode Voltage: 100~600V, (48~60HZ) adjustable, when the short-circuit current at 1.0±0.1A, the voltage goes down less than 10%. The liquid drop device can make the liquid height from 30~40mm (adjustable), drops liquid size is 44~55 drops/1cm3. The interval drops of liquid is 30s±5s (adjustable). During the testing, the short-circuit current is more than 0.5A to keep 2 seconds, then shut off current, it show the sample not pass. Inside dimension: 0.5CBM and outside dimension: 630mm*390mm*750mm.
-
product
Galvanic DO Sensor
Model 20
The Model 20 Galvanic DO Sensor utilizes proven galvanic sensing technology – without a question the most accurate and reliable DO sensing technology ever developed. The pure platinum cathode makes the sensor incapable of being poisoned by other gases often found in impure waters, such as hydrogen sulfide. This sensor utilizes the only DO sensing technology that is successful in continuous de-nitrification monitoring and control applications. It is also the only sensor design that can be used continuously in very violent pure liquid oxygen injection systems. Complete systems are supplied with over 5 years of sensor electrolyte and membranes.
-
product
Capillary-fill sensors
Zimmer and Peacock have launched the world's first capillary fill sensor for the Research and Development market, both academia and industry. We provide these capillary-fill sensors in gold, platinum and carbon.
-
product
RTD Thermometers
Precision Platinum Temperature Sensor, High Accuracy With 0.01°C Resolution, Automatic Locked Push-pull Connector For Easy Connection, Large Back Light LCD
-
product
Solar Panel Compact Walk-in Chambers
ENX112
The ENX112 chambers provide a test chamber large enough for testing full-size PV modules in the least amount of floorspace. Can be use for panels 1.2m x 2m or larger.These models provide a variety of performance capabilities to meet maximum or minimum change rates in IEC or UL test standards. Incorporated are the features of our smaller Platinum and Global-N lines. The refrigeration systems of these models utilize modern, high performance scroll compressors that allow a small footprint while allowing unparalleled service access.
-
product
16-Channel VME RTD/Resistance Input Module
V410
The V410 is a 6U VME module that provides sixteen independent analog inputs that may be used to read RTDs, thermistors, and other similar resistive sensors. It can also read cryogenic diodes. Users may set input range and adjust other settings at VMEbus speed, and depending on the range selected the microprocessor will do the necessary calculations and output voltage, resistance, or temperature. Temperature conversion is available for 100Ω and 1000Ω, series 385 and 392, platinum RTDs.
-
product
Platinum and Nickel RTD Temperature Sensors
Accurate, repeatable and robust resistance temperature detector (resistance thermometers) sensor assemblies manufactured provide fast temperature response and can be applied in most temperature measurement and control applications.
-
product
Working Electrodes for Flow Cell
Our working electrodes for flow cell are mounted in blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hardness and organic slovent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purporses.
-
product
Citadel CTD-ES
Teledyne Marine RD Instruments
The CITADEL CTD-ES incorporates proven inductively coupled conductivity sensor technology with a platinum resistance thermometer and micromachined silicon pressure sensor to provide highly accurate and stable readings.
-
product
Dual MAX31865 PT-1000 RTD to Digital Breakout
SEN-30202-PT1K
Dual channel breakout board for the MAX31865 RTD-to-Digital converter from Maxim. Two breakout hardware configurations are available standard, designed to interface with either the PT100 or PT1000 platinum RTDs. For non-standard applications, including thermistors, custom hardware configurations can be accommodated. Contact Technical Support for more information.
-
product
Precision Thermometer
F252
ASL's F252 provides high accuracy, dual channel temperature measurement with Platinum Resistance Thermometers - PRTs - and uses AC bridge technology as developed by ASL for Standards Laboratories throughout the world. Model F252 requires no regular recalibration, the AC circuit techniques eliminating thermal EMFs and drift, while providing excellent long term stability. Front panel data entry allows you to enter probe calibration data into the F252's memory, so that thermometer resistance can be accurately converted to temperature in C, F or K. This can be password protected to prohibit unauthorised or accidental data entry.
-
product
Digital Melting Point Apparatus
DRK8011
Shandong Drick Instruments Co., Ltd.
DRK8011 Digital melting point apparatus is fully in line with ‘humanize’ of the design concept, using photoelectric automatic detection, dot matrix image LCD technology, digital keyboard input, each measuring one sample, measure three times the average of the melting point of the automatic strike, and has a melting, melting end automatically, melting curve automatic recording function. Temperature system uses high inearity make platinum resistance sensing element, the use of PID regulationtechnology to improve theaccuracy and reliability of the melting point, and with integrated electronic circuits to achieve rapid "starting temperature" setting and eight stalls to choose from linear "heating rate" Automatic Control. Instrument to establish communication with the PC via USB, save or print the graph, the instrument can be directly connected with the RS232 mini-printers, print graphs. The instrument uses Pharmacopoeia as a sample capillary tube.
-
product
RJ45 Port Saver
#21025C
Extend the life of your tester by using the RJ45 PortSaver as your sacrificial cable. Eliminates the wear and tear from constantly plugging in and out of the tester port and minimizes the risk of damaging the RJ45 jack if the connector contacts are not crimped completely. Compatible with all Platinum Tool testers with built-in […]
-
product
High-Temperature and High-PressurepH Electrodes
UltraDeg
Corr Instruments offers a full range of exceptionally high performance, high-temperature and/or high-pressure UltraDeg probes, including pH electrodes, reference electrodes, platinum conductivity probes, and ORP(redox) electrodes, for temperatures up to 650F (343C) and pressures up to 5100 psi (35 MPa). These probes are ideal tools for corrosion monitoring, thermodynamic or electrochemical studies in harsh environments such as steam generators, nuclear power reactors, geothermal systems, deep oil/gas wells, and super critical water systems. Many of these UltraDeg probes are built upon our innovative sealing compound, Queon, which is the only known material in the world for sealing electrical conductors in metal sealing glands or compression feedthroughs that are operable at temperatures between 400F (200C) and 650F (343C).
-
product
Temperature Transmitter
Knick Elektronische Messgeräte GmbH & Co. KG.
Transmitters for platinum temperature sensors and thermocouples in 6 mm housing with calibrated range selection. Functional safety up to SIL 2, SIL 3 redundant to parameterization via interface or intuitively, directly on the device. Universal use with 24 V DC or AC power supply.
-
product
Tone And Probe Kit
#TP150
Make cable tracing easy with Platinum Tools’ Tone and Probe Set. With its steady tone, push-to-scan button and a clear loudspeaker, quickly trace and identify cable locations on jacks or through walls. Wire bundles are easily penetrated with the tapered probe tip and the probe volume is controlled with a thumbwheel. With common send and […]
-
product
Gold Purity Tester
PRO‑ALLOY
The Easy Way To Test Gold & Platinum Jewelry. Measure the purity of rings, chains, watches and more… Instant gold karat reading • Fast and accurate • Non-destructive.
-
product
Cross Flow Cell
Working electrodes for flow cell are mounted on blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hard, organic solvent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purposes. Thin Layer Cell has been used as a electrode for research such as flow injection analysis (FIA) and the HPLC.
-
product
Reference Thermapen®
Until now you would have spent hundreds more to get this level of accuracy in a NIST-Traceable standards thermometer. Our Reference Thermapen takes lab accuracy into the field. Each unit is factory calibrated at 5 test points and includes a UKAS accredited calibration certificate with test data. A true "system calibration" is performed matching its Platinum RTD sensor and the built-in electronics so all errors are included in the spec.
-
product
Power Meters and Calibration Cells
The Solar Reference Cell consist of a 20 x 20 mm monocrystalline silicon Photovoltaic Cell encased in a 92 x 70 x 16 mm metal enclosure with a protective quartz window and a temperature sensor. The temperature sensor is a 100 ohm platinum Resistance Temperature Detector (RTD).The Solar Reference Cells come with a Certificate of Calibration and compatible set of connecting cables. The following parameters of the reference cell are certified: Isc, Imax, Voc, Vmax, Pmax, Area, Fill Factor and Efficiency. The certification is accredited by NIST to the ISO-17025 standard and is traceable both to the National Renewable Energy Laboratory (NREL), and to the International System of Units (SI). A compatible cable set is also supplied with each Solar Reference Cell.
-
product
High and Low Temperature Humidity Chamber
GDJS/GDJW
•The chamber is produced by SUS304 Steel, the temperature keeping material is produced by Polyurethane hard foam and ultra-fine fibre glass, the doorframe heat insulated by Double high temperature aging silicone rubber door sealing strip. •The temperature controller is used by Korean TEMI display in English/Chinese and German Siemens PLC, it can be communicated to PC via RS-232. The temperature accuracy is 0.1℃ and humidity is 0.1%R.H •The temperature sensor is platinum PT100 Ohms/MV resistor •The heating system is full separately system which produced by Nickel chromium alloy electric heating type heater •The cold system is applied by fully enclosed fan cooled single-stage and cascade refrigeration mode, the compressor is from France TECUMSEH brand which can allow you get after sales support from many countries •The cyclical system is applied by High temperature low noise air conditioning type motor and Multi blade centrifugal wind wheel •The safety self-protection function include Electric leakage, short circuit, over temperature, motor overheating, compressor pressure, overload, over-current protection •Working Power: AC380V±10% 3phases and frequency 50Hz/60Hz •Working Environmental: Temperature is 5℃~+30℃ Humidity ≤85%R.H
-
product
Micro Melting Point Instrument
DRK8026
Shandong Drick Instruments Co., Ltd.
Determine crystal melting point of the substance to make sure its purity. Mainly used for determining the meltingpoints of medicine,dyestuff,spice and other organic crystal compounds.Using photoelectric automatic detection, Dot matrix LCD display picture technology, digital keyboard input, and has the initial melting, final weld automatic display,automatic recording of melting curve, automatically determine the melting point of the mean value function. The temperature system uses highly linear platinum resistance as detection elements and PID regulation technology, improved the melting point’s precision and reliability. The instrument establishes communication with PC through the USB or RS232, printing or saving the curve and it uses capillary Pharmacopoeia as sample tube.
-
product
Salinity Testers
Labodam pocket salinity testers are equipped with platinum sensors, providing fast and reliable results measuring the salinity of water and other low and high salt concentrated solutions. Equipped with replaceable electrodes, helping to reduce maintenance cost.
-
product
Pocket Conductivity Testers
Labodam pocket conductivity testers are equipped with platinum sensors and 1 point brush calibration system. These easy to use pocket conductivity meters come with waterproof design features for protection against harsh conditions. The conductivity meters can be used for measuring the conductivity of drinking water, waste water, brine water, and liquids with high, low conductivity.
-
product
Diode Temperature Monitor
SIM922
Stanford Research Systems, Inc.
The SIM922 Diode Temperature Monitor and the SIM923 Platinum RTD Monitor are designed to measure four sensors simultaneously. Based on the modular SIM platform, they provide high-performance and multiple-channel capability in a small footprint.
-
product
Solar Panel Reach-in Chambers
ENX48Solar Panel Reach-in Chambers
Your first choice for a medium-size test chamber for PV module testing is ESPEC's ENX48.These models provide a variety of performance capabilities to meet maximum or minimum change rates in IEC or UL test standards. Incorporated are the features of our smaller Platinum and Global-N lines. The refrigeration systems of these models utilize modern, high performance scroll compressors that allow a small footprint while allowing unparalleled service access.





























