- Pickering Interfaces Inc.
product
Dual Bus 75-Channel 2A PCI Fault Insertion Switch
50-190-002
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
product
Insertion / Return Loss Tester
JW8301
Shanghai Joinwit Optoelectronic Tech,co.,Ltd
JW8301 Insertion/Return Loss Test Station is a professional instrument, which is designed for CWDM device, multi-wavelength devices, PLC, fiber cable. It is a new high precise optical test instrument, which combines many years experiences of passive device ,configured with VFL and 850nm Optical Light Source. It supports the judgment of threshold, Multi wavelength automatic testing, system integration, upper computer monitor solution etc.
-
product
Bench-top Insertion & Return Loss Test Station
STC-IRL3201
Shanghai Stone Communication tech Co., Ltd
STC-IRL3201 is a high performance loss test station that is designed specially for Optical Passive Components production Test and Lab Test. It combines three different working modes as a return loss meter, optical power and loss meter and a stable laser source in one test station.
-
product
Handheld Return Loss Tester
JW3308
Shanghai Joinwit Optoelectronic Tech,co.,Ltd
JW3308 handheld return loss tester is used to measure the return loss in the field fiber optic linking, in order to adjust the quality of the optic fiber end-face, and to make sure the fiber optic communication is in good condition. This 3308 handheld return loss tester can realize measurement of Return Loss, Insertion Loss, Output power, and also can be used as the laser source. Moreover, it has the data storage function of 500 measurement items.
-
product
Optical Return Loss Meter
ORL
•Four functions in one•Power meter and light source•Return loss meter and insertion loss meter•3 wavelength detection(1310/1490/1550nm)•Rugged, shock and water-proof for field use•Compact size, lightweight and cost-effective•Quick and easy to operate
-
product
Insertion Loss Test Set
OptiConcepts FiberWarrior Pro™ Insertion Loss Test Set is used for the following functions: continuity check, fiber loss, return loss, and connector loss for OEM, lab, and production use as well as transport, metro, access, and FTTx/PON networks. The FiberWarrior Insertion Loss Test Set performs single-mode and multimode loss measurement functions, including single component and multi-fiber testing.
-
product
Optical Loss Test Set (OLTS)
MaxTester 940/945
First tablet-inspired, multifunction optical loss test set (OLTS) delivering insertion loss, optical return loss and fiber length measurements at two wavelengths in five seconds via fully automated bidirectional FasTesT™ analysis. With its step-by-step reference wizard and intelligent fault diagnosis, the MAX-940/945 provides expert guidance throughout the test process to ensure immediate efficiency by first-time users while removing risk of errors or negative loss—a common source of issues when testing low loss fibers.
-
product
MPO/MTP MANDREL FREE IL/RL LOSS TEST STATION
Shanghai Fibretool Technology Co.,Ltd.
FBT-M24 mandrel free insertion loss test station is specially design for multi fiber testing. It realized mandrel free return loss measurement on the multi fiber, and without matching gel for the MM measurement. This test station also do the auto-testing on 12 core (24 core) for insertion loss and return loss, highly efficient multi-core fiber insertion and return loss measurement and make high precision on the measurement result with OTDR mandrel free technical adopting.
-
product
2-Channel Mandrel Free IL/RL Test Station
Shanghai Fibretool Technology Co.,Ltd.
This test station is designed specially for different connector on both sides patch cord(such as FC-SC, FC-LC, SC-LC…) and the duplex patch cord.The REF for insertion and return loss can set one time for those kind of patch cord, no need to change standard patch cord and interchange testing port connector on tester( Especially 2.5mm and 1.25mm interchange). For the tested patch cord, APC end no need to manually set standard patch cord length if PC end measured shortest length is 2.2M.
-
product
Automotive Ethernet Channel Compliance Software
AE6910L
The Whole Communications Channel represents the complete wired connection between two transmit / receive modules with an automotive Ethernet interface using a two-wire twisted pair cable. The Keysight AE6910L software ensures signal quality requirements, with conformance testing for that channel. In addition, it performs return loss, insertion loss, mode conversion, and power sum cross talk measurements of a cable in a bundle.
-
product
Coaxial Power Dividers
A coaxial 2-way power splitter with a typical insertion loss of 1.2 dB at each output port and a typical isolation of 16 dB across the frequency range of 1 to 18 GHz. The power splitter has a nominal power handling of 30 W (CW) and a typical amplitude unbalance of ±0.4 dB. The return loss for all ports is 13 dB typical. The RF connectors of the power splitter are female SMA connectors.
-
product
DC Block, 50 kHz to 26.5 GHz
N9398C
The Keysight N9398C DC block offers a new level of DC blocking with performance specified from 50 kHz to 26.5 GHz. This DC block features a broad frequency range, excellent return loss, very low insertion loss and excellent temperature stability.
-
product
DC Block, 50 kHz to 50 GHz
N9398F
The Keysight N9398F DC block offers a new level of DC blocking with performance specified from 50 kHz to 50 GHz. This DC block features a broad frequency range, excellent return loss, very low insertion loss and excellent temperature stability.
-
product
DC Block, 700 kHz to 26.5 GHz
N9399C
The Keysight N9399C DC block offers a new level of DC blocking with performance specified from 700 kHz to 26.5 GHz. This DC block features a broad frequency range, excellent return loss, very low insertion loss and excellent temperature stability.
-
product
DC Block, 700 kHz to 50 GHz
N9399F
The Keysight N9399F DC block offers a new level of DC blocking with performance specified from 700 kHz to 50 GHz. This DC block features a broad frequency range, excellent return loss, very low insertion loss and excellent temperature stability.
-
product
DC Block, 700 kHz to 67 GHz
N9398G
The Keysight N9398G DC block offers a new level of DC blocking with performance specified from 700 kHz to 67 GHz. This DC block features a broad frequency range, excellent return loss, very low insertion loss and excellent temperature stability.
-
product
Fixed Laser Source Module
Keysight offers a broad choice of fixed laser sources, which are available as single-wavelength and dual-wavelength modules as part of the Keysight Lightwave Solution Platform. The Keysight 8165xA Fabry-Perot laser sources can be used in conjunction with optical power meter modules for insertion loss, optical return loss and PDL measurement of broadband components and fiber. The Keysight 81663A Distributed Feedback Laser Sources are best suited for amplifier test and WDM system test applications...show more -
product
Flexible Cable, 2.4 Mm To 3.5 Mm
85134H
The Keysight 85134H is a 62.9 cm (24.75 in) long1 flexible cable with a 2.4 mm female2 to 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz with a return loss greater than or equal to 16 dB. Insertion loss is 0.31 * sqrt (f) + 0.2 (where f is frequency is GHz) for the test port connector and 1.8 dB at maximum frequency for the device connector. Phase stability of semi-rigid/flexible cables is characterized with a 90 degree bend using a 2.5 inch radius. Stability1 of the Keysight 85134H is less than 0.12 dB and phase is less than 0.13o * f + 0.5o, (where f is frequency in GHz).
-
product
Flexible Cable, 3.5 Mm (Test Port) To 3.5 Mm
85131H
The Keysight 85131H is a 62.2 cm (24.5 in) long1 flexible cable with a 3.5 mm female2 to 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz with a return loss greater than or equal to 16 dB. Insertion loss is 0.25 * sqrt (f) + 0.2 dB (where f is frequency is GHz) for the test port connector, and 1.5 dB at maximum frequency for the device connector. Phase stability of semi-rigid/flexible cables is characterized with a 90 degree bend using a 3 inch radius. Stability1 of the Keysight 85131H is less than 0.12 dB and phase is 0.13o * f + 0.5o, (where f is frequency in GHz).
-
product
Flexible Cable Set, 2.4 Mm To 3.5 Mm
85134F
The Keysight 85134F is a 62.9 cm (24.75 in) long1 flexible cable set composed of a 2.4 mm female2 to PSC-3.5 mm female connector and a 2.4 mm female2 to 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz with a return loss greater than or equal to 16 dB. Insertion loss is 0.31 * sqrt (f) + 0.2, where f is frequency in GHz, for the test port connector and 1.8 dB at maximum frequency for the device connector. Phase stability of semi-rigid/flexible cables is specified with a 90 degree bend using a 4 to 3 inch radius. Stability1 of the Keysight 85134F is less than 0.12 dB and phase is 0.13*f+ 0.5°, where f is frequency in GHz.
-
product
Flexible Cable Set, 3.5 Mm (Test Port) To 7 Mm
85132F
The Keysight 85132F is a 62.9 cm (24.75 in) long¹ flexible cable set composed of two 3.5 mm female² to 7 mm connectors. Cable frequency range is dc to 18 GHz with a return loss greater than or equal to 17 dB. Insertion loss is 0.25 * sqrt(f) + 0.2, where f is frequency in GHz, for the test port connector and device connector. Phase stability of semi-rigid/flexible cables is specified with a 90 degree bend using a 4 to 3 inch radius. Stability¹ of the Keysight 85132F is less than 0.12 dB and phase is 0.13 * f + 0.5, where f is frequency in GHz.
-
product
High-Power Low-Loss Pulsed Bias Tees
MBT series
The MBT-series of bias tees is based on Maury's patented broadband capacitor (US Patent 9,614,267) which simultaneously enables the industry's widest bandwidth, lowest insertion loss and lowest return loss in a coaxial bias tee up to 18 GHz. In addition, its unique design makes it ideal for pulsed applications, including pulsed IV and pulsed load pull characterization, without distorting the voltage and current waveforms.
-
product
IL/RL Testing Platform
JW18001
Shanghai Joinwit Optoelectronic Tech,co.,Ltd
To meet the test requirements of MPO devices, we adopt the JW18001 optical device testing platform,JW1608 No-mandrel IL/RL tester module, JW1606 multi-channel optical switch module and form an integrated solution for MPO testing. The application of No-mandrel technique solves the problem that the multi-core optical device can not be winded and needs fiber matching cream, thereby the testing efficiency of the insertion loss and return loss of the multi-core / ribbon fiber has been greatly improved. At the same time, MPO applications can configure a variety of testing mode, test reports, threshold setting function, so multi-core optical device testing is no longer complicated.
-
product
LISN & Voltage Probes
All commercial LISNs include an artificial hand connection and a transient limiter. This adds a 30dB insertion loss. A 30dB pre-amplifier is included which can be connected in the RF output feed to return the insertion loss to 0dB. The Voltage Probe requirement is covered by our PLIP (Power LIne Interference Probe). This fully meets the requirements of CISPR16, but has additional features:*Fully galvanic isolation between input and output (>1kV), for the safety of operator and analyser!*Shrouded safety clips for attachment to the line to be measured.*Filtered frequency response matched to Band A and B.*Current limiting on the output.*Visual indication of high voltage input.
-
product
N-Male to F-Male Test Cable
C75NMFM
The C75NMFM is a high performance 75 Ohm test cable that is ideal for performing lab grade measurements 75 Ohm environments. It supports high accuracy testing with low insertion and excellent return loss up to 3GHz as well as outstanding mechanical durability.
-
product
N-Male to N-Male Test Cable
C75NMNM
The C75NMNM test cable is a high performance 75 Ohm test cable that is ideal for performing lab grade measurements 75 Ohm environments. It supports high accuracy testing with low insertion and excellent return loss up to 3GHz as well as outstanding mechanical durability.
-
product
PCIe Passive Switch
MAX4889C
High-Speed PCI Express Passive Switches Enable Gen II Switching with Low Insertion Loss and Superior Return Loss
-
product
PCIe Passive Switch
MAX4889B
High-Speed PCI Express Passive Switches Enable Gen II Switching with Low Insertion Loss and Superior Return Loss
-
product
PIN Solid State Switch, 100 MHz to 18 GHz, SP4T
P9404C
The Keysight P9404C PIN solid state switch maximizes your operating frequency range from 100 MHz to 18 GHz. Providing superior performance in terms of isolation, insertion loss and return loss, the P9404C is particularly suitable for high-speed RF and microwave switching applications such as switch matrixes in instrumentation, communications and radar. These switches provide ultra-fast switching speed to increase throughput in manufacturing.
-
product
PIN Solid State Switch, 100 MHz to 18 GHz, SPDT
P9402C
The Keysight P9402C PIN solid state switch maximizes your operating frequency range from 100 MHz to 18 GHz. Providing superior performance in terms of isolation, insertion loss and return loss, the P9402C is particularly suitable for high-speed RF and microwave switching applications such as switch matrixes in instrumentation, communications and radar. These switches provide ultra-fast switching speed to increase throughput in manufacturing.
-
product
PIN Solid State Switch, 100 MHz to 8 GHz, SP4T
P9404A
The Keysight P9404A PIN solid state switch maximizes your operating frequency range from 100 MHz to 8 GHz. Providing superior performance in terms of isolation, insertion loss and return loss, the P9404A is particularly suitable for high-speed RF and microwave switching applications such as switch matrixes in instrumentation, communications and radar. These switches provide ultra-fast switching speed to increase throughput in manufacturing.