Impedance
-
product
High Impedance Differential Clock Divider
Alliance Support Partners, Inc.
he ASP-DCD-00 board is a high impedance input clock divider circuit. It is designed to provide minimum load to a clock source for frequency measurement. It accept single ended (Unbalanced) or differential (Balanced) signals with amplitudes as little as 100mV rms; it divides the input signal frequency from 2 to 256 times depending on shunt jumper selections on J3. The board requires 5VDC 500mA power source to operate. The output is capable of driving 5V TTL logic levels.
-
product
Standard 0.80 (22.00) - 4.00 (114.00) High Frequency Probe
CSP-03G-003
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 3.70Return Loss @ -20dB (GHz): 1.80Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,090Overall Length (mm): 27.76
-
product
Impedance Stabilization Network
Beijing KeHuan Century EMC Technology Co,.LTD
KH8158 is a device for measuring the common mode interference voltage of unshielded twisted pair cables. Cable testing according to CISPR 16-1-2. The equipment under test (EuT) and auxiliary equipment (AE) are directly connected to the corresponding ports. The port adopts RJ-45 socket (the distribution conforms to T568A/B.) This equipment is divided into three specifications: CAT3, CAT5, and CAT6, and the corresponding equipment is selected according to the cable model.
-
product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40B-012
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
product
Calibration Kit
S911T
*S911T Calibration Kit, * Frequency Range: up to 9 GHz, * Impedance: 50 Ohm, * Connector Type: 3.5 mm female.
-
product
PCIe-Mini
PCIe-Mini-AD8200
8 Channels 16-bit A/D converter Simultaneously Sampled• Fast throughput rate: 200 KSPS for all 8 channels• 8 Channels SE or 4 PSEUDO Differentials• Single-ended or 4 differential channels• True bipolar analog input ranges: ±10 V, ±5 V, selection applies to all Channels• Analog Input Clamp Protection• 1MΩ Analog Input Impedance• Programmable 2nd Order Anti-alias Analog Filter• Over-sampling capability with digital filter• 8Kx16 SRAM• PCIexpress compliant
-
product
LCR Meters And Impedance Measurement Products
Complete impedance measurement solutions to meet your needs from LCR to impedance meters, plus test accessories for various R&D and manufacturing applications.
-
product
High Impedance Probes
Everbeing offers GGB’s high impedance active probe for failure analysis of your devices. The high impedance with low capacitive design allows measurements of internal nodes without loading the device. For more information, please visit http://www.ggb.com.Everbeing offers GGB’s high impedance active probe for failure analysis of your devices. The high impedance with low capacitive design allows measurements of internal nodes without loading the device. For more information, please visit http://www.ggb.com.
-
product
Micro Coax, Contact, ITA, RG316
610141101
Primary mating contact 610140101. (May mate with other Receiver contacts, as well.)Mechanical SpecificationsDurability 10,000 cyclesContact Material Center Conductor – BeCuShield – BrassContact Plating 50µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC – 3 GHzVSWR 1.22 @ 3 GHzInsertion Loss – √f(GHz) x .06 dBDWV 800 V RMSContact Resistance 6 mOhms center/4 mOhms outer Cable Specifications RG316Environmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
Low Impedance Voltage Tester
K-60
K-60 KNOPP VOLTAGE TESTER for AC and DC with polarity indicator. Double safety indication is by solenoid and by neon lamp. Knopp’s K-60 Low Impedance Voltage Tester (Cat. 14460) offers portability and ease of use with full protection. These exceptionally versatile and useful tools are backed by a reputation for quality in the design and manufacturing of electrical test equipment.
-
product
Micro Coax, Contact, Receiver, 50 GHz
610140108
Primary mating contact 610141108. (May mate with other ITA contacts, as well.) *This contact sold as a patchcord only.Mechanical SpecificationsDurability 10,000 cyclesContact Material Center Conductor – BeCuShield – BrassContact Plating 30µ" Au over 100µ" NiContact Termination Solder Nut ClampInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC-50GHzVSWR 1.06+0.004 f(GHz)Insertion Loss - .095 x √f(GHz) dBDWV 700 V RMSContact Resistance 6 mOhms center/4 mOhms outer Cable Specifications Flex 405Environmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
Impedance Analyzer / LCR Meters
When used together with the PSM range of frequency response analyzers, the N4L impedance analysis interfaces provide a measurement solution to many impedance analysis applications. The most appropriate interface for a specific application will depend upon the nominal impedance of the sample or device being tested and the frequency of measurement and N4L will be happy to discuss the optimum soution to any application. Reasons to choose an N4L Impedance Analyzer
-
product
The Leading Measurement System for the Analysis of Porous Materials
ELWIS
ELWIS (Evaluation of Light Weight Impedance System) offers a full and rapid characterization of porous materials based on the analysis of a single sample. The ELWIS system consists of the ELWIS-A and ELWIS-S components which can be used independently from each other although both applications are needed for a complete material simulation.ELWIS-A measures acoustic parameters that are needed to evaluate the acoustic performance of sound insulation and sound-absorbing multi-layer materials. An additional impedance tube for absorption measurements at higher frequencies is available for ELWIS-A.ELWIS-S measures structural parameters that are needed to simulate the dynamic and acoustic behavior of sound packages in the medium to low frequency range (including the "Poisson Ratio" for foam materials).ELWIS is very easy to operate: Thanks to its user-friendly software, the system can also be used to obtain reliable results by users with only limited experience in the characterization of porous materials.
-
product
Vector Network Analyzers
The VIA Bravo is a handheld Vector Impedance Analyzer for measuring the impedance and resonant frequencies of circuits and antennas. The VIA Bravo has the capability of providing accurate measurements and sweep displays of impedance, reactance, resistance, phase angle, return loss and SWR. The VIA Bravo’s testing functionality, combined with its 100 kHz to 200 MHz frequency range, make it a versatile tool for many service applications including areas such as MRI, wireless telemetry, 2-way radio, aviation, and Radio Frequency Identification (RFID).
-
product
Mini Coax, Contact, ITA, Solder Sleeve, RG316 & RG178
610103140
Mini Coax, Contact, ITA, Solder Sleeve, RG316 & RG178.Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating Shield – 50µ" Au over 100µ" NiCenter Conductor – 60µ" Au over 100µ" NiContact Termination Solder SleeveInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC to 2 GHzVSWR ≤ 1.2 @ 2 GhzInsertion Loss ≤ 0.05 dB @ 500 Mhz≥ -0.3 dB @ 2 GhzDWV 1500 VDC Min.Contact Resistance < 5 mΩ @ 0.5 Amp & always < 10 mΩCable Specifications RG316 & RG178Environmental SpecificationsOperating Temperature -50°C to +105°CInsulation Resistance 1000 MΩ min.
-
product
PNMDF3.5F NMD 3.5mm F to 3.5mm F Adapter
PNMDF3.5F Adapter, NMD 3.5mm F to 3.5mm F, Frequency ,Range: up to 26.5 GHz, Impedance: 50 Ohm
-
product
Loop/Line Impedance Testers
Shanghai Beha Electronics Co., Ltd.
*Built-in earth tester.*Built-in loop/psc tester. 0.03 - 2000Ω (software ctrl).*Built-in voltmeter.*Built-in wiring checker.*One push button smart control.
-
product
Coax, Contact, Receiver, 75 Ohm HD, sm59/U Belden 1855A, 3 GHz
610102133
Primary mating contact 610102132. (May mate with other ITA contacts, as well.)Mechanical SpecificationsDurability 20,000 cyclesContact Material Female & Male Shield – BrassCenter Contact – BeCuContact Plating Center Conductor Shield – 30µ” Au over 100µ” NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 2.0 lbs max [0.91 kg]Electrical SpecificationsCharacteristic Impedance 75 ΩFrequency Range DC to 3 GHzVSWR ≤ 2.26 @ 3 GHzInsertion Loss -0.86 dB MaxDWV 1500 VDC min.Contact Resistance 5 mΩ center/ 3 mΩ outer Cable Specifications sm59/U Belden 1855AEnvironmental SpecificationsOperating Temperature -55°C to +125°CVibration MIL-STD 1344, Method 2005, Test Condition 4Shock MIL-STD 1344, Method 2004, Test Condition EInsulation Resistance 1000 MΩ min.
-
product
Impedance Analyzer
TH2839
Changzhou Tonghui Electronic Co., Ltd.
■ Freq: 20Hz-10MHz, max. resolution 1mHz ■ Test Accuracy: 0.05% ■ Test Speed: Max.7.7ms ■ Auto-balance bridge technology, 4-terminal pair
-
product
High Impedance Active Probes
12C
A high speed, high input impedance active probe for measuring the internal node voltage of integrated circuits. The input is 1 megohm shunted by 0.1 pf and the rise/fall times are 0.8 ns. This instrument has full dc capability and can be used with any oscilloscope. The Model 12C was specially designed so that when used in conjunction with a high input impedance oscilloscope, signal attenuation is 10:1 and with a 50 Ohm input, signal attenuation is 20:1.
-
product
High Impedance Active Probes
28 AND 29
Designed to serve the needs of integrated circuit engineers working in the most advanced high speed, submicron, MOS technology. These high frequency instruments include the attractive features of the Models 18C and 19 including full dc capability, negligible dc current drain, and extremely low input capacitance. In addition the frequency range of the Models 28 and 29 has been extended to a full 1 GHz.
-
product
Mini Coax, Contact, Receiver, RG316
610104114
Primary mating contact 610103115. (May mate with other ITA contacts, as well.)*This contact available as a patchcord only. Please select link below to configure a patchcord.Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating Shield – 50µ" Au over 100µ" NiCenter Conductor – 60µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC to 1 GHzVSWR ≤ 1.06 @ 1 GhzInsertion Loss 1.2 dB @ 1 Ghz1.02 dB @ 500 MhzDWV 1500 VDC Min.Contact Resistance ≤ 5 mΩCable Specifications RG316Environmental SpecificationsOperating Temperature -50°C to +105°CInsulation Resistance 1000 MΩ min.
-
product
Impedance Stabilization Networks
ISN
They are required for the measurement of conducted common mode noise on Telecom Cables of Information Technology Equipment (ITE). These measurements are necessary to meet the requirements specified in CISPR 22 and CISPR 32 standards.
-
product
Coax, Contact, ITA, 20 GHz, RG 223, Crimp, 90 Series Modules only
610102117
Primary mating contact 610102116. (May mate with other ITA contacts, as well.)20 GHz coax contacts have an impedance of 50 Ohms and a current rating of 5 amps.It is recommended to use SF142 to achieve 20 GHz and RG223 to achieve 12 GHz.Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating 30µ" Au over 100µ" NiContact Termination Shield – Crimp/ClampInsulator PTFEMating Force 3.0 lbs max [1.36 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC to 20 GHzVSWR 1.15 + .01 (f) GHz w/ RG142 (8 GHz)1.15 + .01 (f) GHz w/ SF142 (20 GHz)Insertion Loss .06 x√f(GHz) dBDWV 800 V RMS Shield to center contact1000 V RMSContact Resistance 5 mOhms center/ 3 mOhms outer Cable Specifications RG 223 Environmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
Antenna Analyzer
Measuring antenna SWR ratio with graphic display in a selected frequency range.Measuring antenna Impedance ( Z = R + j X )Measuring antenna resistance RMeasuring antenna reactance X, all the above with graphic display in a selected frequency range.Quick search for antenna resonance frequencyVery suitable for antenna measurement and adjustment.Portable and small size.Easy and intuitive operation
-
product
Micro Coax, Contact, ITA, RG316 Double Shield
610141104
Primary mating contact 610140104. (May mate with other Receiver contacts, as well.)Mechanical SpecificationsDurability 10,000 cyclesContact Material Center Conductor – BeCuShield – BrassContact Plating 50µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - SolderInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC – 10.5 GHzVSWR 1.0225 +.05 f(GHz)Insertion Loss – √f(GHz) x .06 dBDWV 800 V RMSContact Resistance 6 mOhms center/4 mOhms outer Cable Specifications RG316 Double ShieldEnvironmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
Arbitrary Load-Impedance X-Parameters
S94520B
S94520B Arbitrary Load Impedance X-parameters enables an X-parameter model to be collected over a user defined set of load impedances. S94520B still requires an application to control the load impedance such as S94521B or Maury ATS or IV Cad.
-
product
Precision Impedance Analyzer
TH2851-130
Changzhou Tonghui Electronic Co., Ltd.
■ Test frequency: 10Hz-130MHz ■ High precision: using automatic balance bridge technology, four-terminal pair test configuration ■ High stability and consistency ■ High speed: the fastest test speed up to 5ms
-
product
Localized Electrochemical Impedance Spectroscopy
VS-LEIS
The VersaSTAT 3F applies an AC voltage to the sample emerged in electrolyte. This "global" voltage generates AC current to flow at the electrode / electrolyte interface. A dual-element probe is positioned in solution close to the surface of the sample. The electrometer measures a differential voltage measure between the two measurement elements as a measure of local voltage-drop in solution. This voltage-drop exists in solution because of current flow from local reactions at the sample, the resistance of the electrolyte and the spatial separation of the dual measurement elements.
-
product
Vector Network Analyzer
Bode 100
With the multifunctional Bode 100 you get an exact picture of your electronic circuits and components in a frequency range from 1 Hz to 40 MHz. The Bode 100 is not only a state of the art Vector Network Analyzer, it also works as: Frequency Response Analyzer, Impedance Meter, Gain Phase Meter, Sine Wave Generator.





























