Filter Results By:
Products
Applications
Manufacturers
-
product
Ground Resistance Clamp Meter
61-920
*Auto ranging*Auto power off*Hard case included*2-year warranty
-
product
Earth Ground Resistance Meter
1623-2
The Fluke 1623-2 earth ground tester measures earth ground loop resistances using only clamps, only stakes, or one clamp and stakes. With the stakeless test method, the Fluke 1623-2 is able to measure earth ground loop resistances for multi-grounded systems using only current clamps.
-
product
Earth Ground Tester
1625-2
The Fluke 1625-2 earth ground tester measures earth ground loop resistances using only clamps, only stakes, or one clamp and stakes. With the stakeless test method, the Fluke 1625-2 is able to measure earth ground loop resistances for multi-grounded systems using only current clamps. This technique eliminates the dangerous, and time consuming job of disconnecting parallel grounds, and finding suitable locations for auxiliary ground stakes.
-
product
High Voltage Insulating Tester
Suitable for preventive maintenance of gapless arresters.By simply clamping around the ground wire of an arrestor with a clamp CT, it detects leak current and leak current resistance components.
-
product
Earth Ground Clamp
1630-2
The 1630-2 FC clamp measures earth ground loop resistances for multi-grounded systems using the dual-clamp jaw. This test technique eliminates the dangerous and time-consuming activity of disconnecting parallel grounds, as well as the process of finding suitable locations for auxiliary test stakes.
-
product
Easy Pole Clamp-On Ground Resistance Tester w/ Super Slim Jaw
FT6380
The FT6380 measures grounding resistance simply by clamping to multiple-grounded ground wires. No auxiliary grounding rod is needed, and there is no need to disconnect the ground wire from the grounding rod. The compact, low-profile sensor can be used to clamp ground wires with ease, and also provide AC current measurement functionality and can measure currents ranging from leakage current on the order of several mA to load currents of up to 60 A.
-
product
Ground Fault Finder
FST-JD200 DC
Foresight Electronics Co., Ltd.
FST-JD200 not only can provide a solution on accurately testing the faults of the indirect-grounding of the direct current system, non-metal grounding, loop grounding, simultaneous grounding of the anode and cathode, balanced grounding of the anode and cathode and multi-point grounding 1. The high-precision sampling clamp meter The device uses a high resolution (0.1mA) signal sampling direct current clamp meter that can achieve multi-point grounding and high resistance ground point positioning...
-
product
Digital Ior Leakage Current Clamp Tester
MCL-400IR+
MULTI MEASURING INSTRUMENTS Co., Ltd.
・About Ior Leakage CurrentRecently, the leakage current clamp meter is widely used for insulation control of low voltage circuit as the supplementary method of the insulation resistance measurement. The control of leakage current has the advantages to enable the prediction of insulation condition in the electrical power line without having to shut off the power. The leakage current (Io) includes the capacitive leakage current (Ioc)originated in the capacitance and the resistive leakage current (Ior) originated in the insulation resistance each related to the ground. It is considered that the measurement of resistive leakage current (Ior) is the very useful and effective method for the insulation control of low voltage circuit. However, it was difficult to measure the resistive leakage current (Ior)with traditional leakage current clamp meter. MCL-400IR new digital clamp tester enabled the measurements of the resistive leakage current (Ior)without voltage input(phase detection).
-
product
Ground Grid Tester
GGT Series
The GGT500 ground grid integrity tester is designed for inspection of the substation ground grid. It can also be used as a portable micro-ohmmeter with Both Sides Grounded and Remote Control functionalities. It is intended to inspection the conditions of a grounding system beneath substations, testing of medium- and high-voltage circuit breakers, disconnecting switches, high-current bus bar joints, cable splices, and different high-current links.In the United States when inspecting the quality of the grounding systems beneath a substation, the proper procedure is to inject 300 A DC during a time period of 60 s. This is what the GGT500 will do, and in that time period, the current path and voltage drop are checked. Also acting as a micro-ohmmeter, the GGT500 can test low resistance values by producing high test currents of up to 500 A.The instrument is placed in an unbreakable, plastic case with IP67 protective rating (with closed lid). Although very portable and lightweight, micro-ohmmeters have very high output power capabilities. High output voltage enables a wider measurement range at higher test currents, as well as the use of thinner/longer test cables. GGT500 ground grid integrity tester generates a true DC ripple-free (less than 1 % ripple) current with automatically regulated test ramps. This significantly decreases magnetic transients and ensures great accuracy.When used for testing in Both Sides Grounded conditions, a special current clamp powered from the ground grid integrity tester is used for measuring a current through groundings. If even a higher safety level is required, the remote control feature enables the operator to perform measurements from a distant location, away from the instrument and test object.