- Pickering Interfaces Inc.
product
Single Bus 75-Channel 2A PCI Fault Insertion Switch
50-190-001
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 4 Channel
50-200-004
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 8 Channel
50-200-008
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
product
Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 4 Channel
50-201-004
This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, Broad R-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.
-
product
Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 8 Channel
50-201-008
This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.
-
product
Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 4 Channel
40-201-004
This high bandwidth differential fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external sig...show more -
product
Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 8 Channel
40-201-008
This high bandwidth differential PXI fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external...show more -
product
PXI-2510, 68-Channel, 2 A PXI Signal Insertion Switch Module
778572-10
68-Channel, 2 A PXI Signal Insertion Switch Module—The PXI‑2510 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2510 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
40-203-001
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
42-203-001
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 6-Channel
40-203-002
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 6-Channel
42-203-002
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
Ground Fault Detectors
STB Electrical Test Equipment, Inc
STB's convenient Ground Fault Detectors may be operated with one hand and are ideal for preventative maintenance. Ground Fault Detectors indicate ground faults and electrical leakage while equipment is in operation.
-
product
Ground Fault Finder
FST-JD200 DC
Foresight Electronics Co., Ltd.
FST-JD200 not only can provide a solution on accurately testing the faults of the indirect-grounding of the direct current system, non-metal grounding, loop grounding, simultaneous grounding of the anode and cathode, balanced grounding of the anode and cathode and multi-point grounding 1. The high-precision sampling clamp meter The device uses a high resolution (0.1mA) signal sampling direct current clamp meter that can achieve multi-point grounding and high resistance ground point positioning...
-
product
Ground Fault Location
Kongter Test & Measurement Co., Limited
Kongter offers a whole line of ground fault locator from basic to advanced model to fast detect, trace and pinpoint virtual grounding faults in DC systems when systems are LIVE (working online). Without injecting any signal to the DC system, they are safe to your existing system. With Kongter’s unique technique for signal tracing, these ground fault locators are much faster and more effective to find the earth fault in the field than its peers.
-
product
Ground Fault Locator
K-800
Kongter Test & Measurement Co., Limited
Kongter’s K-800 Ground Fault Locator is the new model which is developed to fast detect, trace and pinpoint virtual ground faults in LIVE DC systems where electrical cables have breakage with current lost to ground.
-
product
Ground Fault Locator
GFL-1000
The GFL-1000 ground fault locator is used to pinpoint faulty grounding where electrical cables have breakage and lost to the ground. The GFL-1000 is recommended by NERC PRC-005-2 to inspect for unintentional grounds for VLA, VRLA and NiCad batteries every four calendar months. Included software allows for data management analysis.
-
product
Ground Fault Locator
K-3837
Kongter Test & Measurement Co., Limited
Kongter’s K-3837 Ground Fault Locator is developed to fast detect, trace and pinpoint virtual grounding faults on LIVE DC systems with earth fault. It will save you from long time unnecessary troubleshooting and helps to increase the stability of your electrical equipments. It is widely used in various DC systems including power utilities, locomotive, telecom and etc.
-
product
Ground Fault Locator
DC Trace
SCOPE introduces DC Trace, the most advanced and user friendly DC Earth (Ground) Fault Locator. This portable instrument consisting of Signal Generator & Signal Receiver (DC TraceR) uses latest digital signal processing technology. It’s ability to detect earth faults in live DC system quickly & accurately in online condition greatly relieves the substation maintenance engineers from nightmare of earth leakages & it’s detection.
-
product
Ground Fault Monitor
IFT-120
Our ground fault monitors enable you to easily and quickly find the source of the fault before a major problem occurs and damages your equipment. This is the IFT-120, designed to assist you in rapid identification of ground faults.
-
product
DC Ground Fault Finder
FST-JD200
Foresight Electronics Co., Ltd.
FST-JD200 not only can provide a solution on accurately testing the faults of the indirect-grounding of the direct current system, non-metal grounding, loop grounding, simultaneous grounding of the anode and cathode, balanced grounding of the anode and cathode and multi-point grounding 1.
-
product
DC Ground Fault Locators
We currently offer one highly capable DC ground fault locator for sale to the United States, Canada and Globally. This fault locator is highly reliable and highly capable of locating any ground fault in a variety of settings. This one piece of ground fault locator equipment is all you will ever need to find any fault, in any location, in any system. With advanced computations and fuzzy logic it can very accurately display the insulation level of the tested circuit. We offer the best and only ground fault locator you will ever need. To learn more about his product please click below where you will also be provided key features and the ground fault locator specifications.
-
product
Ground Fault Analyzers and Detectors
The Model 760 detects and locates accidental ground faults on both energized and de-energized power circuits including single phase, three phase, and DC ungrounded systems.
-
product
Ground Fault Protection Monitors
The Earth Fault Resistance Monitor (EFREM) and the Rotor Health Monitor (RHM) provide wireless rotor ground fault and temperature monitoring for generators and motors. The systems replace older slip ring contact ground fault detectors on any synchronous generator or motor.
-
product
Under Ground Cable Fault Locator
Widely used in electrical and power generation sector for testing underground cables in order to detect any fault.
-
product
5mA High Accuracy Ground Fault Detector
HA-GFD
Our HA-GFD Current Probe is our most sensitive current probe, measuring down to 5 milliamps. Ideal for measuring leakage current and ground faults. Dual range allows measuring up to 200 amps in high accuracy.
-
product
Ground Detection and Earth Fault Location Equipment for Ungrounded or Floating DC Systems
ZX3
The ZX3 is a ground fault locator that finds grounds (current leakage) on a battery system positive rail, the negative rail, on both rails simultaneously, in a field device, battery bank or solar array/string, regardless if they are high resistance or low resistance or in a capacitive environment. It also can provide more information about the DC ground than any other equipment available, providing maximum analyzing capabilities.
-
product
Fault Locator
VM-510FFL+
Finding the location of an underground cable fault just became easier with the VM-510FFL+ Standalone A-frame locator. Now locating a suspect cable and finding the fault can be done with the VM-510FFL+ and a compatible transmitter. There is no longer a need for a separate utility locator with cables connecting to it. After connecting a compatible transmitter to the line and placing it in a Fault-Find mode, use the simple to operate four button controls of the VM-510FFL+ to locate and stay on the cable path while pinpointing the sheath or ground fault.
-
product
Battery Ground Detector
BGD
Battery Ground Detectors supply contact closures for alarm indications at precise ground fault resistance settings.
-
product
Field Ground Module
SEL-2664
Schweitzer Engineering Laboratories, Inc.
Add the SEL-2664 Field Ground Module to the SEL-300G or SEL-700G to protect all the critical components in your generator with one comprehensive relay. Or, add the SEL-2664 to the SEL-2664S to complete ground fault protection on both the rotor and stator.