Filter Results By:

Products

Applications

Manufacturers

Control

Known value


Showing product results. 6721 - 6735 of 6879 products found.

  • PXIe, 145 MHz Bandwidth, 16-Bit, 128 MB, I/Q PXI Waveform Generator

    PXIe-5450 / 780419-01 - NI

    PXIe, 145 MHz Bandwidth, 16-Bit, 128 MB, I/Q PXI Waveform Generator—The PXIe‑5450 is a 145 MHz, dual‐channel arbitrary waveform generator optimized for I/Q communications signals. It is an ideal instrument for testing devices with I/Q inputs, or as the baseband component of an RF vector signal generator. The PXIe‑5450 also features onboard signal processing (OSP) functions that include pulse shaping and interpolation filters, gain and offset control, and a numerically controlled oscillator (NCO) for frequency shifting. The PXIe‑5450 also features advanced synchronization and data streaming capabilities.

  • PXIe, 18-Slot (16 Hybrid Slots, 1 PXI Express Slot), Up to 12 GB/s PXI Chassis

    PXIe-1086 / 781720-01 - NI

    PXIe, 18-Slot (16 Hybrid Slots, 1 PXI Express Slot), Up to 12 GB/s PXI Chassis - The PXIe‑1086 incorporates hot-swappable, redundant AC power supplies as well as hot-swappable, front-accessible, redundant cooling fans. These high-availability features improve the mean time between … failure (MTBF) and mean time to repair (MTTR) of the PXI system. The PXIe‑1086 monitors power supply health/voltages, air intake temperature, and fan health/speed; it provides any failure feedback with the status LEDs located on the chassis. This chassis is ideal for test, measurement, and control applications with demanding system uptime requirements.

  • 1M Gate Virtex-II FPGA, Digital Reconfigurable I/O Device

    PCI-7811 / 779363-01 - NI

    The PCI‑7811 is a reconfigurable I/O (RIO) device that features a user-programmable FPGA for onboard processing and flexible I/O operation. With LabVIEW FPGA, you can individually configure the digital lines as inputs, … outputs, counter/timers, PWM, encoder inputs, or specialized communication protocols. You can also program custom onboard decision making that executes with hardware-timed speed and reliability. The PCI‑7811 is well-suited for a wide variety of applications, such as high-speed waveform generation, sensor simulation, hardware‑in‑the‑loop (HIL) test, custom communications protocols, bit error rate test, and other applications that require precise timing and control.

  • Circuit Breaker Analyzers & Timers

    CAT Advanced Series - IBEKO Power AB

    DV Power circuit breaker analyzer and timer utilizes the latest technological enhancements for safe and fast testing of circuit breakers. The sophisticated design ensures efficient and reliable operations in high-voltage substations and industrial environments.The CAT Advanced series are stand-alone or PC-controlled digital instruments for a circuit breaker testing. The timing channels record closing and an opening of the arcing, resistor, and auxiliary contacts. Also, the main contact channels can measure the resistance value of the pre-insertion resistors (if present in the circuit breaker).With CAT Advanced series instruments, it is possible to record graphs of open and close coil currents. Furthermore, it records displacements of the HV and MV circuit breaker moving parts. Test results can be saved via USB, PC or be printed via 112 mm (4.4 inches) thermal printer (optional accessory) in tabular and graphical form.A circuit breaker test consists of different operational modes and CAT Advanced series supports:Open (O)Close (C)Reclose (O-0,3s-C)Trip free (CO)O-0,3s-COOpen-Close (O-C)Close-Open (C-O)Open-Close-Open (O-C-O)First trip (O)Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by sensing a breaker’s contact position.The auxiliary inputs are used to monitor dry and wet auxiliary contacts. The six coil control analog channels measure and record coil currents simultaneously (OPEN and CLOSE), up to 35 A AC/DC.The additional six voltage analog channels have four selectable voltage ranges available (±1 V, ±5 V, ±60 V and ±300 V AC/DC).A built-in micro-ohmmeter generates up to 500A true DC ripple-free current with an automatically regulated test ramp that provides performing static and dynamic contact resistance measurement.Three transducer channels provide a measuring displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time and average velocity. Also, a user can connect either an analog or a digital transducer to these universal channels.

  • Climatic Chamber

    Wewon Environmental Chambers Co, Ltd.

    Climatic chamber is designed to do high temperature & high humidity, high and low temperature, or temperature cycling test, Climatic chamber mainly used for quality checking and assessing their quality reliability and life test. ● The climatic chamber simulate a full range of temperature testing and humidity testing conditions.These chambers are designed for ease-of-use, reliability and performance and include many user-friendly features standard with your purchase for the best value in the industry. ● Climatic test chambers are able to provide rapid product temperature change rates and use varying levels of relative humidity to locate design problems prior to shipping your products, improving product quality and reliability. climatic chamber For conditioning of samples prior to testing. Climatic chamber also can be used for a variety of materials of high – low temperature alternating test. The test temperature, humidity, time can be programmed. Provides conditions of temperature form -70 degree to +150 degree and of humidity from 20% to 98%. ● This type climatic chamber use 16bit Industry-grade PLC, programmable controller to control the test temperature test, and recycle time, more excellent anti jamming, high reliability of the data. ● TEMI880 large color LCD touched screen temperature & humidity controller. Real-time display program running time, the number of segment, the remaining time, repeat frequency,can display experimental data, including the pre-set segment time, heating status, calendar time, etc; climatic chamber directly digital display. ● Climatic chambers apply controllable silicon step-less adjusting technology to adjust temperature and humidity test continuously and precisely, and without over heated as the PID adjusting function. ● The thermal insulation material between outside and inside for climatic chamber is high-quality ultra-fine glass fiber insulation cotton, good thermal insulation effectivity. Thermal insulation layer composed of flame fire PU + glass wool insulation (insulation thickness 10.0 cm)

  • Paper Moisture Meters

    PCE Instruments

    A paper moisture meter measures the humidity of paper and paper products. Use of a paper moisture meter can prevent costly damages resulting from paper expansion or shrinking. A paper moisture meter determines paper moisture content based on either absolute humidity or relative humidity. Absolute humidity does not take into consideration temperature, while relative humidity relies on temperature and is expressed as a percentage of the total amount of moisture possible at the current temperature. Thus, many paper moisture meter devices feature automatic temperature compensation (ATC).For paper producers, paper manufacturers, paper mills and others in the pulp and paper industry, moisture and humidity control is essential, especially during the production process, as excessive moisture can lead to warming of the paper rolls. A paper moisture meter can be used to detect moisture streaks during the paper production process as well as to identify optimal drying times.Regardless of whether paper is stored in paper rolls in paper converting plants or stacked in sheets and paper bales in commercial printing warehouses, the porous surface of paper gradually takes in moisture relative to the humidity of the surrounding environment. This moisture can be problematic, as too much moisture can cause curling, buckling or the formation of waves in otherwise flat paper products. Moisture also can prevent inks, dyes, paints and coatings from covering and saturating paper properly during printing and processing.PCE Instruments (PCE) offers digital handheld moisture meter devices for measuring the moisture content of paper and paper products such as cardboard, paperboard, corrugated boxes, craft paper, wrapping paper, brown packaging paper, butcher paper, recycled paper, coated paper and more. Different paper moisture meter models utilize different paper moisture measuring techniques, performing moisture content tests of paper products via either destructive or nondestructive methods. Typically, a standard pinless paper moisture meter is nonpenetrating, thus allowing for the nondestructive measurement of paper water content.

  • HBM Verification Tester

    HBM-VT - High Power Pulse Instruments GmbH

    - HBM pulse generator verification tester according ANSI/ESDA/JEDEC JS-001 up to ±10kV- To be used in HBM test and qualification labs for regular pulse generator specification compliance test in order to fulfill lab audit and certification requirements- Fully automatic compliance test and verification of HBM pulse generators regarding ANSI/ESDA/JEDEC JS-001 normative standard at 3 different load conditions: Short Circuit, 500 Ω, and a reference diode at VBR=15 V reverse breakdown voltage, including DC test- Parameter evaluation and verification of the transient HBM current waveforms: Peak Current, Rise Time, Decay Time, Maximum Ringing Current- Optionally available upgrade for all HPPI TLP-3010C, 4010C, 8010A, 8010C, HBM-TS10-A hardware systems in combination with HBM-S1-B (6kV) pulse generators (upgrade on request)- Fully automatic test report generation (PDF)- Electrically floating (no fixed system ground): The HBM loads, current sensor output, USB control interface and the enclosure are electrically floating. There is no limiting system ground which may introduce common-mode interference induced HBM current measurement errors.- Isolated industrial full-speed USB control interface- Isolated power supply derived from USB port- Compact size 126mm x 82.5mm x 44.5mm

  • EQCM Electronic Quartz Crystal Microbalance

    Elettra - BioAge s.r.l.

    Elettra has been designed to operate on its own, but it is also possible to connect it to a PC to control it and acquire, view and save data thanks to its extremely easy to use software that runs under MS-Windows™. The data acquisition process can be controlled extremely quickly thanks to the PLAY, PAUSE and STOP keys. Captured data can be saved in an Excel compatible format and graphs saved as bitmap images. By clicking on a button, the software is able to open the Excel program installed on the PC, enter all the data and create countless graphs, ready to be inserted in your documents and publications. At any moment it is possible to take a picture of the graph showing the frequency variation and save it as a bitmap image, to be able to insert it in documents and publications. The same keys that are present on the instrument are found on the software, these allow you to control the instrument remotely. On the frequency variation graph it is possible to zoom in on the regions of interest, it is also possible to display two cursors on the graph, thanks to these cursors it is possible to easily and immediately calculate the value of the frequency variation between any two points on the graph. The software is extremely easy to use and performs many other useful functions, such as automatic recognition of the computer port to which the instrument is connected. BioAge builds tools and writes software only after having carefully listened to the needs and requirements of the users of the final products, this process has the purpose of creating products that are easily usable and that have all the characteristics and functions that the user expects to have.

  • DC Resistance Tester

    ZLD-10 - Shanghai Dean Electrical Co., Ltd

    Executive standard: GB/T4074.5-2008/IEC60851-4; Inspection standard: JB/T4279.2-2008Used to measure conductor with nominal diameter ≥0.01~9.0mm or various round or flat copper and aluminum wires and other metal wires with DC current resistance of 100μΩ~99.99Ω;Combination of intelligent DC conductor resistance measuring meter and DC resistance test fixture with sample straightening function;Test range can be selected according to the resistance value of sample, and after clamping samples current resistance value would be displayed;Both potential fixture and current fixture are made of copper;The application of microcomputer control allows for full-automatic completion of test;LED will intuitively display measurement results;

  • 903 Benchtop Three Phase 40A

    Weshine Electric Manufacturing Co., Ltd

    1. The instrument has standard four phase voltage and three-phase current output. It can test not only various traditional relays and protection devices, but also various modern microcomputer protections, especially for transformer differential protection and standby automatic switching device. The test is more convenient and perfect.2. Classic Windows XP operation interface, friendly man-machine interface, easy and fast operation; high performance embedded industrial control computer and 8.4 inch resolution 800 × 600 TFT true color display screen, can provide rich and intuitive information, including the current working state of the equipment and various help information.

  • Random Access Monochromator

    DeltaRAM X - HORIBA, Ltd.

    The patented DeltaRAM™ X microscope Illuminator is the ideal fluorescence illuminator for quantitative intracellular ion research. It utilizes a galvanometer-based Random Access Monochromator (RAM) that can switch between any wavelength in 2 milliseconds. The DeltaRAM™ X is a complete, self-contained, illuminator that includes a power supply, high intensity xenon light source, DeltaRAM™ X monochromator, TTL shutter and flexible liquid light guide. The wavelength position is a simple analog voltage control. All you need to add is a microscope adapter for your fluorescence microscope and a USB or PCI DAC interface depending on the software you will be using to drive the illuminator.

  • Wide-range Output Programmable DC Power Supplies

    PPA1500 Series - Twintex Electronics Co., Ltd

    PPA series are high precision programmable DC power supply with auto range output, output power rated 400W, 800W and 1500W, maximum rated voltage up to 1200V. PPA series offer the widest range of output voltage and current at its rated power. One PPA power supply can cover output range of multiple power supplies. It offers powerful programming function through RS232 and RS485 intefaces, supporting SCPI and Modbus-RTU commands. And it is designed to meet both bench-top and integrated system applications. It is the most economical choice of power source to facilitate auto test and auto control.

  • Electromagnetic Immunity Scanner

    SmartScan BASIC - Amber Precision Instruments

    The BASIC is manually operated system for performing susceptibility scanning at the system level with minimal data storage capability. This system includes:1. Up to 8kV (optional. 4kV base) pulse generator for ESD susceptibility testing- Camera and camera shutter to take DUT picture and failing spots- Control computer2. Up to 8kV Probe Sets:- 1mm Hx/y Field Probe- 5mm Hx/y Field Probe- D=8mm Hz Field Probe- D=8mm Ez Field Probe- Contact API for custom design probes3. Manual input of testing location and failing condition over the DUT to be included in final report.

  • Data Acquisition System

    Ajinkya Electronic Systems

    Available with us is Data Acquisition system that includes data loggers, scanners, various instruments spread all over the plant, SCADA / Monitoring Software on central PC and multiple SCADA software running along the plant under supervision of central PC. We offer data loggers and other instruments support MODBUS communication protocol that can be connected on a data acquisition bus if it is running on MODBUS protocol. Most of the popular SCADA software available support MODBUS communication. We have a wide range of products apart from Data loggers, Scanners and Event Loggers which can be part of data acquisition and control system, such as

  • MassLynx Mass Spectrometry Software

    Waters Corporation

    The challenges of MS and MS/MS analyses are often compounded by the use of several types of analytical instruments and high personnel turnover. To maintain – and even increase laboratory productivity, turn to Waters software to simplify interaction with your MS system and retain the ability to perform advanced experiments. Waters MassLynx™ Software improves your MS system with its intuitive interface, intelligent instrument control, and software features built around the focus of your analysis: the sample. With much of its development driven by input from our extensive user base, MassLynx has evolved into a powerful software package that delivers the versatility and flexibility you require.

Get Help