-
product
EDX-FTIR Contaminant Finder/Material Inspector
EDXIR-Analysis Contaminant Finder/Material Inspector
EDXIR-Analysis software is specially designed to perform qualitative analysis using data acquired by an energy dispersive X-ray (EDX) fluorescence spectrometer and a Fourier transform infrared spectrophotometer (FTIR). This software is used to perform an integrated analysis of data from FTIR, which is excellent at the identification and qualification of organic compounds, and from EDX, which is excellent at the elementary analysis of metals, inorganic compounds and other content. It then pursues...show more -
product
EDXIR-Analysis Contaminant Finder/Material Inspector
EDXIR-Analysis software is specially designed to perform qualitative analysis using data acquired by an energy dispersive X-ray (EDX) fluorescence spectrometer and a Fourier transform infrared spectrophotometer (FTIR). This software is used to perform an integrated analysis of data from FTIR, which is excellent at the identification and qualification of organic compounds, and from EDX, which is excellent at the elementary analysis of metals, inorganic compounds and other content. It then pursues...show more -
product
Sample Holder/Stocker For Contaminant Measurement
EDXIR-Holder
Measure the Samples Kept in the Holder with EDX and FTIR The Holder Can Be Used as the Sample Stocker after the Measurement
-
product
1TB NAND SATA Drive
XMC-554C
Curtiss-Wright Defense Solutions
The XMC-554C is a rugged, high performance, reliable and power-efficient NAND flash solid state drive (SSD) solution. The XMC-554C does not have any moving parts, providing significantly lower power consumption and an order of magnitude improvement in reliability in environments with vibration and contaminants, compared to traditional rotating hard disk drives (HDD).
-
product
Application Specific LC Systems
Nexera Amino Acid Analysis System
Amino acid analysis occupies an important role in diverse fields such as food science and pharmaceutical manufacturing. Nexera Amino Acid Analysis System uses detection by post-column fluorescence derivatization, with o-phthalaldehyde (OPA)/N-acetylcysteine as the reaction reagents, to selectively and with high sensitivity quantitate the amino acids contained in samples with high levels of contaminants.
-
product
Archival Storage Rooms
Darwin Chambers Company’s NFPA, GSA, and NARA Directive 1571-compliant Archival Storage Chambers are engineered to provide maximum value, efficiency and conformance with all applicable standards and codes. Archival chambers provide environmental controls for storing records and materials (including paper documents and items with high fibrous content, various films, microfiche, and photographic materials) that require permanent protection for storage and preservation. Our high-performance systems...show more -
product
Biosafety Testing
Biological products derived from mammalian cell lines pose an inherent risk for the introduction of microbial or viral contaminants. In addition, the manufacturing process or product itself may introduce impurities that must be characterized.
-
product
Bulkflow X-Ray Inspection System
Designed to be integrated into line with optional reject stations, the Bulkflow X-ray System is perfect for loose and free flowing products. Offering a good detection levels on a wide range of contaminants including all metal, bone, glass and dense plastics.
-
product
Chloride/Sulfate Analyzer
Thornton 3000CS
The METTLER TOLEDO Thornton 3000CS Analyzer is an on-line instrument for direct measurement of chlorides and sulfates in pure water and power cycle chemistry samples. The analyzer continuously monitors these highly corrosive contaminants to assist in corrosion control and minimizing damage to critical power plant equipment. Early, unambiguous detection of trace levels of chloride and sulfate ions is provided with minimal operator supervision.
-
product
Cleaning
Air Knives
Fraser Anti-Static Techniques Ltd
Produce fast-moving ionised air which can neutralise static electricity and remove contaminants.
-
product
Cleaning
Air Guns
Fraser Anti-Static Techniques Ltd
For neutralising static electricity and removing dust and other contaminants.
-
product
Contaminometer
Conttest
Microtronic Microelectronic Vertriebs GmbH
Ionic contaminants can have a major negative impact on the reliability of assemblies. It therefore makes sense to check the assemblies for ionic contamination in the development stage and in the manufacturing process.The devices of the ConTTest series measure ionic pollution in accordance with international standards. The high-precision measuring system was designed to serve as a process control in production and to be used as a laboratory instrument in development and research.
-
product
Digital Dust Monitor
3443
The Kanomax Digital Dust Monitor – Model 3443 measures aerosol concentrations corresponding to PM10. The intake isolates the aerosol sample so that the optics chamber is kept sterile for improved reliability and low maintenance. The unit measures 0.1 to 10µm particle size aerosol contaminants such as fumes, dust, smoke and mists. It is battery-operated, data-logging, light-scattering laser photometer that gives you real time aerosol mass readings. It is also suitable for clean office settings well as harsh industrial workplaces, construction and environmental sites, and outdoor applications.
-
product
Dual Input Handheld Digital Thermometer
820A
Model 820A dual input, digital, thermometers are compatible with type K or J thermocouple probes to provide temperature measurements from -346F to 2502F. The heavy-duty case is designed for durability and resistance to external contaminants such as dust and chemicals. The case has a built-in tilt bail for hands-free or bench top operation.
-
product
Environmental Testing
Intertek Total Quality Assurance environmental laboratories test client samples around the world for trace chemical compounds and pollutants. Environmental chemists operate state-of-the-art analytical instrumentation, testing to government, regulatory, and industry standards. Analytical capabilities include trace and ultra-trace analysis for hydrocarbons, petrochemicals, metals, contaminants, and other materials.
-
product
Extreme Environment Sensors
Kaman Fuzing & Precision Products
For high pressure, low temperature, and high temperature applications* For applications requiring high accuracy, high reliability, and structural integrity.* Operating temperatures from -320°F to +1000°F (+1200°F short term).* Displacement systems withstand pressures up to 3500 or 5000 psi.* Dual-coil sensor design effectively minimizes radiation effects.* Hermetically sealed and laser welded.* Unaffected by environmental contaminants.
-
product
Filters, Collectors, Separators, Purifiers
Parker's filters, separators and purifiers come in a variety of options and media and are used to filter out air or fluid contaminants in an array of industrial and commercial applications.
-
product
First Trip Testing of Circuit Breakers
Significance of Circuit Breaker "First Trip Time"A circuit breaker may not be called upon to operate and clear a fault for years, but when a fault occurs, it is expected to operate within it's published time-current characteristics. Unfortunately, frequently this does not happen... environmental contaminants, hardened grease, vibration and other factors can adversely affect the operating time of the circuit breaker.
-
product
Fixed Gas Analyzer
BIOGAS 3000
Introducing our new fixed gas analysis system, the BIOGAS 3000! Primarily for the Anaerobic Digestion (AD) biogas and bio-methane upgrading market, the BIOGAS 3000 has been designed to enable site operations to maximize gas production yield and protect expensive capital equipment from the damaging contaminant gases contained within the production process.
-
product
Flow Indicators
Flow indicator with rotor features a self-cleaning mechanism to ensure full visibility of the rotor at all times. Typical sight flow indicators suffer from poor indicator visibility through normal use from build-up that impedes observation of the rotor through the viewing window. Typically, for a sight flow indicator to be cleaned, it must be removed from the pipeline, cleaned and then replaced at some specified time, such as during plant shutdown. Unfortunately, dirt build-up does not typically...show more -
product
Food Monitoring Systems
Is a system of repeated examination, measurement and evaluation of levels of undesirable substances, such as plant protection products, heavy metals and other contaminants, in and on food.
-
product
Fourier Transform Infrared Spectrophotometer
IRTracer-100
This system achieves excellent sensitivity with an SN ratio of 60,000:1, high resolution at 0.25 cm-1, and high-speed scanning capable of 20 spectra/second. The performance of medium and higher end models is supported by high reliability including advanced dynamic alignment and an interferometer with a dehumidifier. This is compatible with applications active in a variety of circumstances, with a library of approximately 12,000 spectra and data analysis programs for contaminant analysis, and time course and rapid scan programs for reaction tracking.
-
product
Futura Series
The Futura Analyzer Series of dedicated continuous-flow wet chemistry analyzers identify and measure contaminants in water and soil using a melange of technologies capable of handling both simple and complex analyses. The systems are fully automated and measure many parameters, such as phenols, cyanides, detergents, total phosphorus, total nitrogen, and many more.
-
product
High-concentration, High Flow Ozone Generator
SEMOZON® AX8407
The SEMOZON AX8407 generator converts pure oxygen into ozone through silent electrical discharge and achieves high output and high concentration level. It requires only minute levels of dopant nitrogen gas, far below the levels required for competitive ozone generators. As a result, the presence of contaminants, e.g. NOx compounds, is extremely low.
-
product
High Voltage Inclined Plane And Erosion Tester
SCR ELEKTRONIKS have developed HIGH VOLTAGE INCLINED PLANE AND EROSION TESTER to carryout test specified in many standard to cover test method for the evaluation of the relative tracking and erosion resistance of insulating solid using liquid contaminant (ASTM D2303). Perform the Initial Tracking Voltage Test, Time to track Test, And Erosion Test as per selection.
-
product
Humidity Sensors
digital humidity sensor with integrated temperature sensor that provides excellent measurement accuracy at very low power. The device measures humidity based on a novel capacitive sensor. The humidity and temperature sensors are factory calibrated. The innovative WLCSP (Wafer Level Chip Scale Package) simplifies board design with the use of an ultra-compact package. The sensing element of the HDC1008 is placed on the bottom part of the device, which makes the HDC1008 more robust against dirt, dust, and other environmental contaminants. The HDC1008 is functional within the full 40C to +125C temperature range.
-
product
Inductor Products
Macom Technology Solutions Holdings Inc.
They provide uniformity, durability and repeatability in circuit fabrication. The coils are polyimide coated to protect from ambient contaminants, and to eliminate the need for conformal coating. Quartz substrates are rugged and reduce dielectric losses. Chips may be bonded using either conductive or non conductive epoxies, and wire bonded with gold wire or ribbon by thermocompression bonding.
-
product
Laboratory Ferrography
T2FM 500
The SpectroT2FM 500 Analytical Ferrography Laboratory is a complete analytical system for the separation and interpretation of wear and contaminant particles in used lubricant oils, hydraulic fluids, coolants and fuels. It consists of the T2FM Ferrogram maker, a bichromatic microscope, video camera and image capture software.
-
product
Laser Process Analyzers
LGR-ICOS Series
LGR-ICOS laser process analyzers accurately measure gas concentrations with extraordinarily high sensitivity, fast response and over a wide dynamic range in both simple and complex mixtures. They are ideal for contaminant monitoring in HyCO (syngas), fuel gas, petrochemicals, and semiconductor fabrication facilities.
-
product
Long Term Test Kit
When long term electro-chemical tests (>1000 hours) are run to monitor the cell degradation at the cathode for example, it is important to avoid any contaminant in the gas flow rate.Inconel 601 flange equipped with alumina housing and alumina tube to feed the gas to the electrode during long term test (>1000 h)Typical poisoning is coming from the chromium contained in the steel tubing. The volatile chromium species (Cr6+) will flow into the cathode (with the air) and thanks to th...show more