Filter Results By:
Products
Applications
Manufacturers
EUT
Equipment Under Test
-
product
LISN Line Impedance Stabilisation Networks / AMN Artificial Mains Network
A LISN Line Impedance Stabilization Networks / AMN Artificial Mains Network: *supplies the neccessary mains voltage (AC or DC) and current for the Equipment under Test (EuT).*couples interference voltage generated by the EuT and supplies it to the receiver.*provides well defined RF-impedance to the Equipment under Test (EuT)*keeps away unwanted disturbance coming from mains (filter)*protects the mains from unwanted disturbance voltage generated by the EuT
-
product
TDK Software
TDK Software - Testlab, Emissions Lab, Cundicted Immunity Lab, Radiated Immunity Lab, EUT Monitoring Lab, GTEM Emissions Lab
-
product
Aging and Life Test Rack
SY2036
SY2036 Aging and life test rack is fully designed according to the IEC standard, and can also be designed based on the customer request. SY2036 can test LED, CFL, HID Indoor lamp and Outdoor lamp. Input Power supply: AC220V, 50/60HZ, 12KVA Min (110V is option) • Built-in transformer: 0-250V 5KVA and 0-300V 5KVA (Other power is option) • Maximum power for EUT: 5KVA and 12A (Other power is option) • EUT and Number: 112pcs B22, 112pcs E27. 36pcs T5/T8/T12 Tube. 32pcs LED panel (Other EUT can be designed according to customer request) • ON/OFF test: Can be set on the touch screen with program • Test number: 0~99999(Adjustable)
-
product
Conducted Emission
AFJ FFT 3010 & 3030 EMI Receivers have been especially designed for conducted emission measurement, both during EUT diagnostic development and for final compliance testing.
-
product
Three Phase Coupling/Decoupling Network
CDN 3043 Series
- Compliant with IEC 61000-4-4 & 5- Universal teminals- no special plugs required- Safety HV plugs and terminals-Manual/programmable EUT power ON/OFF control- Short term overstress capability
-
product
ESD - Simulator
SESD 216
The test generator SESD 216 simulates electrostatic discharge as defined in the standard IEC / EN 61000-4-2. Depend on the Equipment Under Test (EUT) and the test set-up for laboratory tests the IEC standard shows two test methods
-
product
ESD - Simulator
SESD 230
The test generator SESD 216 simulates electrostatic discharge as defined in the standard IEC / EN 61000-4-2. Depend on the Equipment Under Test (EUT) and the test set-up for laboratory tests the IEC standard shows two test methods
-
product
Soil Testing Complex
GEOMehanika-M
The developed measuring complex for testing soils with "GEOMECHANIKA-M" stamps includes:Control and registration unit: measuring station based on NI cRIO equipment, MIDA overpressure sensor, wireless access point AWK-3131-EU-T, pneumatic system based on pneumatics CamozziLinear motion sensorsWireless Operator Console TestSet of connecting cables
-
product
Ultra-Compact Immunity Tester
AXOS5
The AXOS5 is an ultra-compact immunity tester that performs all the most commonly used transient immunity tests, including Surge, EFT, Dips/Interrupts and AC/Surge Magnetic Field. The simplified user interface provides quick selection of tests and test levels, and even lets you change test parameters “on the fly” while running a test.The actual EUT power mains voltage and current are indicated in the display. Using the Electronic-Fuse function, the user can set an upper limit for EUT power mains current. This feature is useful to protect the EUT from unnecessary damage.Whether you test to the IEC 61000 series “CE Mark” standards, the IEC 60601 Medical Device standards, or any number of telecom and product specific standards, the AXOS5 tester is your one stop test station for everything from precompliance to full compliance to product development testing.A wide range of cost-efficient Coupling / Decoupling Networks for symmetrical and asymmetrical data- and signal-lines is available as an option.
-
product
Ultra-Compact Immunity Tester
AXOS8
The AXOS8 is an ultra-compact immunity tester that performs all the most commonly used transient immunity tests, including Surge, EFT, Dips/Interrupts and AC/Surge Magnetic Field. The simplified user interface provides quick selection of tests and test levels, and even lets you change test parameters “on the fly” while running a test.The actual EUT power mains voltage and current are indicated in the display. Using the Electronic-Fuse function, the user can set an upper limit for EUT power mains current. This feature is useful to protect the EUT from unnecessary damage.Whether you test to the IEC 61000 series “CE Mark” standards, the IEC 60601 Medical Device standards, or any number of telecom and product specific standards, the AXOS8 tester is your one stop test station for everything from precompliance to full compliance to product development testing.A wide range of cost-efficient Coupling / Decoupling Networks for symmetrical and asymmetrical data- and signal-lines is available as an option.
-
product
Customized Test Fixtures
Test fixture is a device designed to mount a device under test (DUT), equipment under test (EUT) and unit under test (UUT) in place and allow it to be tested by being subjected to controlled electronic test signals and procedures.
-
product
Helmholtz Coils
Helmholtz coils is a candidate test apparatus for low frequency magnetic field susceptibility testing on military equipment and subsystems. Use of this coils reduce electromagnetic compatibility (EMC) qualification tests time, and subject the equipment under test (EUT) to a relatively uniform field.
-
product
Visual Inspection Software
AdVISE
R&S®AdVISE visual inspection software automates the process of visually monitoring an equipment under test (EUT) during a test sequence. This eliminates human inattention, ensures reproducible results and simplifies the test documentation. A typical application is EMS testing with R&S®EMC32 and R&S®ELEKTRA test software.
-
product
Filter Design System - Mode Analyser
EA-300
The EA-300 is a stand alone unit with internal firmware and a large colour display. It connects to the outputs from a standard LISN and feeds the results to any standard EMC analyser or receiver. The EA-300 prompts the user through the steps necessary to fully characterise the emissions from the EUT, then will output via the screen the recommended filter component values that would reduce these emissions to acceptable levels.
-
product
Test Software
Elektra
The R&S®ELEKTRA test software controls complete EMC systems and automates measurements of equipment under test (EUT) being certified for emissions (EMI) and immunity (EMS). R&S®ELEKTRA simplifies configuration of test systems and test descriptions in accordance with common standards. It speeds up test execution and paves the way to quickly generating a comprehensive test report.
-
product
Three Loop Antenna
VVLA-30M
The three loop antenna VVLA-30M is a standard measurement antenna according to CISPR15-2005/GB17743-2007 standard
, it can work with LISUN EMI-9KA / EMI- 9KB EMI Receiver System for EUT magnetic field radiation measurement between X, Y and Z planes. The antenna measurement is accurate, switch conveniently and it can completely replace imported products. -
product
Fully-Automated CTIA-Compliant OTA Test System
TS8991
The R&S®TS8991 OTA performance test system measures the spatial radiation and sensitivity characteristic as specified by CTIA and 3GPP.The system software provides ready-to-use test templates for OTA measurements and supports all wireless standards.The integrated report function collects all measured test data such as graphics or numeric results, test environments, EUT information and hardware setup in one document.
-
product
CDN - Coupling / Decoupling Networks
The Coupling- / Decoupling Networks are used to inject common mode disturbances to Equipment under Test (EuT). Further the CDNs provide sufficient decoupling between Auxiliary Equipment (AE) and disturbance signal. The requirements for CDN and their application are described in the standard IEC 61000-4-6 (Immunity to conducted disturbances, induced by radio-frequency fields). CDNs have a common mode impedance of 150 Ohm and are available for a multitude of cable types and connectors.
-
product
Grid Simulator
PAS-F
The Intepro PAS-F Series is a broad line of programmable three phase output regenerative utility grid simulator products. With power levels ranging from 45kVA up to 1.6MVA, the series is capable of testing the largest of dispersed energy inverters. The PAS-F combines utility grid simulation with regenerative bi-directional AC source controlled power that is capable to both source and sink full current from the equipment under test (EUT).
-
product
Ingress Protection: Immersion Water Tests (IPX7 and IPX8)
Ingress protection testing tests the level of protection an enclosure provides against intrusions. One such set of ingress protection tests involves immersing the equipment under test (EUT), in water. These tests are numbered IPX7 and IPX8. The first digit, represented by the “X”, ranges from 0 to 6 and specifies the protection from solid particles. The second digit, in the case of the immersion ingress protection test, would always be a 7 or an 8.
-
product
temperature Measurement
Educated Design & Development, Inc.
Up to 8 resistance reading channels, 4-wire methodUp to 12 temperature reading chanels, use of Type K, 24 AWG, Teflon thermocouplesIn the Box:8 - data cable (Cat5e) to connect the isolation modules to the Resistance Reading Channels8 - Isolation Module connected between the HOT-30 and EUT (Equipment Under Test) to isolate high voltage8 - Banana Jack Sets (2 red, 2 black), to replace Kelvin Leads in tight places8 - Kelvin Probe Set12 - 72 inch K Type Thermocouple1 - USB2.0 Type A (standard) to Type B USB cable
-
product
Harmonics And Flicker Measuring System
ProfLine Series
The Teseq ProfLine system is a complete and cost effective Harmonics and Flicker measurement test system which compiles to the latest IEC/EN standards, including IEC 61000-3-2 and IEC 61000-3-3. The programmable power generation capability of up to 45 kVA (90 kVA and 145 kVA sources comprise multiple 45 kVA units) provides more than ample power to cater for a wide range of Equipment Under Test (EUT).
-
product
Ingress Protection: Dust Protected and Dust Tight (IP5X & IP6X)
Ingress protection testing tests the level of protection an enclosure provides against intrusions. Two such sets of ingress protection tests involve exposing the equipment under test (EUT), to dust. These tests are numbered IP5X and IP6X. The first digit, in the case of dust protected, would always be a 5, and in the case of dust tight, would always be a 6. The first digit, represented by the “X”, ranges from 0 to 9 and specifies the protection from liquid.
-
product
Ingress Protection: High-Temperature and High-Pressure Water Jets Tests (IPX9)
Ingress protection testing tests the level of protection an enclosure provides against intrusions. One such set of ingress protection tests involves exposing the equipment under test (EUT), to high-pressure and high-temperature water jets. These tests are numbered IPX9. The first digit, represented by the “X”, ranges from 0 to 6 and specifies the protection from solid particles. The second digit, in the case of the high-pressure and high temperature water jets ingress protection test, would always be a 9.
-
product
Ingress Protection: Water Jets and Powerful Water Jets Tests (IPX5 & IPX6)
Ingress protection testing tests the level of protection an enclosure provides against intrusions. Two such sets of ingress protection tests involve exposing the equipment under test (EUT), to water jets and powerful water jets. These tests are numbered IPX5 and IPX6. The first digit, represented by the “X”, ranges from 0 to 6 and specifies the protection from solid particles. The second digit, in the case of water jets, would always be a 5, and in the case of powerful water jets, would always be a 6.
-
product
Ingress Protection: Spraying Water and Splashing Water (IPX3 & IPX4)
Ingress protection testing tests the level of protection an enclosure provides against intrusions. Two such sets of ingress protection tests involve exposing the equipment under test (EUT), to spraying water and splashing water. These tests are numbered IPX3 and IPX4. The first digit, represented by the “X”, ranges from 0 to 6 and specifies the protection from solid particles. The second digit, in the case of spraying water, would always be a 3, and in the case of splashing water, would always be a 4.
-
product
Insulation Test Generator
Screw connections on top of the generator, enable easy connection to the EUT. The MIG0603 is the ideal voltage insulation tester with a broad application range. The MIG "Modular-Impulse-Generator" is a flexible kit system, ready to quote tailored generators for special test applications. The MIG is a further innovative solution of EMC PARTNER AG to cover customers requests. The basic units are discharge modules (patent pending) which can be configured in serial or parallel, to offer an optimum solution for the customer need. The use of one type of discharge module guarantees a high reliability and a high qualit . Requires TC-MIG24 or CN-MIG24.
-
product
Biconic Logarithmic Periodic Antennas
Stacked LPDA
The stacked Logarithmic Periodic Dipole Antenna consists of two ordinary Log.-Per. structures. The excellent characteristics (flat gain over a large bandwidth, low SWR) of the ordinary Log.-Per. designs could be maintained using the stacked LP design. The stacked design helps to focus the directional pattern of the H-plane somewhat, resulting in a typical gain improvement of ca. 2-3 dB compared to an ordinary LPDA. This is especially important for immunity testing, where a maximum fieldstrength and a good field uniformity is required. The beamwidth in the E-plane and the H-plane are nearly identical, providing an optimised illumination of the EuT with minimised ground reflection influence. Further the STLP 9128 C has an excellent cross-polar rejection.
-
product
Active Monopole Antenna
AM-741
The 41 inch Monopole antenna is required for making electric field emission measurements below 60 MHz per Military standards (MIL-STD-461) and FAA (DO-160) specifications. This antenna is for emissions measurements only. It cannot be used for transmitting. The Active Monopole antenna is generally used in a shielded room or in a screen room, with the equipment under test (EUT) placed on a metal ground plane. The 41 inch rod and the ground plane behave electrically as though a mirror image of the rod were located below the ground, and the ground removed. Since the stainless steel plate does not have enough surface area to mirror the entire 41 inch rod, it is bonded to the surrounding ground plane during use. The AM-741 is battery powered to prevent measurement errors that maybe caused by external power cables. The ANSI equivalent capacitance substitution (ECSM) method is the recommended method for calibrating AM-741 monopole antenna. The individual calibration data will be included with each antenna.