product
Acute High Voltage Differential Probe, 10x/100x, 100MHz, 700V
ADP1100
*USB Powered (or Power Bank)*Bandwidth up to 10 MHz*Overrange Indicator*Audible Overrange Alarm*Bandwidth Limit : 5 MHz / Full*Can be used by any DSO which has the USB port(s).*EC Declaration: EN 61010-031:2002 +A1:2008*Double-layer wire for power insulation
-
product
Differential Probe
With signals becoming faster, and power supply voltages going lower, these active differential probes will allow floating measurements from 100uVolts to as high as 7000 volts. These probes provide high CMRR and a broad frequency range.
-
product
Differential probe
DP3000 Series
A “differential” probe is an active probe which has two inputs, one positive and one negative as well as a separate ground lead and it drives a single terminated 50Ω cable to transmit its output to one oscilloscope channel
-
product
Differential Probe
DP-800HS
*1:1 High Sensitivity*100 Gain Design*x1, x10, x100 Attenuator*Bandwidth: DC-50MHz*Input Impedance 3MΩ // 2.5PF*Max. 800Vp-p Input or ±400V DC or AC 280V RMS*Output Impedance 50Ω
-
product
Differential Probe
DP-30K
*30KVp-p, High Voltage Model .*Input Impedance 81.6MΩ//1PF *x200, x2000 Attenuator, Easy to Convert.*Separating Design(Standard No.114205)*Convenient & Durable.
-
product
Differential Probe
DP-16K Series
*High Frequency Performance Model*Bandwidth:(-3 dB)**DC~100 MHz (DP-16K)**DC~70 MHz (DP-16KM)**DC~50 MHz (DP-16KL)*2 Range: x100, x1000*Input Impedance:**10 MΩ // 10 pF each side to ground*Over Range Indicate LED*Rise Time: 4 ns
-
product
Differential Probe
DP-15K
DP-15K is a 100mV high sensitivity and able to measure 15KVp-p high voltage and high dynamitic range model.
-
product
Differential Probe
DP-100
*This is the first detachable design (patent for 15 years)*High frequency, big power using. Max. Measuring is 7000Vp-p.I*t is capable for any brand of digital and analog oscilloscopes.*Additional AC Adaptor.*16MΩ high input impedance.
-
product
Differential Probe
DP-60HS
*High Sensitivity Model: x 1, x 5, x 10 Attenuation*1 MΩ // 10PF Input Impedance*High Frequency Operation: x 1(30 MHZ), x 5(60 MHZ), x 10(60 MHz)*Especially For Low Voltage: x 1(7 Vp-p), x 5(35 Vp-p), x 10(70 Vp-p)
-
product
Differential Probe
DP-16V
*MAX. Input Voltage: ±8KV DC or 16KV p-p or AC 5.6KV rms*Bandwidth: DC-50MHz*Input Impedance 30MΩ// 1.5PF*x20, x200, x2000 Attenuator*To Ground MAX. Voltage: 8KV CAT III*Output Impedance 50Ω
-
product
Differential Probe
DP-25
*Econmical High Voltage Model*25MHz/1400Vp-p Max.*3 Range: x20/ x50/ x200*Input Impedance 4MΩ//1.2PF*Separating Design(Standard No.114205) Convenient & Durable.
-
product
Differential Probe
DP-40K
*MAX. Input Voltage: ±20KV DC or 40KV p-p or AC 14KV rms*Bandwidth: DC-20MHz*Input Impedance 100MΩ// 1PF*x500, x5000 Attenuator*To Ground MAX. Voltage: 10KV CAT III*Output Impedance 50Ω
-
product
Differential Probe
DP-08VF
*MAX. Input Voltage: ±400V DC or 800V p-p or AC 280V rms*Bandwidth: DC-150MHz*Input Impedance 20MΩ // 5PF*X20, X200 Attenuator*To Ground MAX. Voltage: 400V*Output Impedance 50Ω
-
product
Differential Probe
DP-8V
*MAX. Input Voltage: ±4KV DC or 8KV p-p or AC 2.8KV rms*Bandwidth: DC-50MHz*Input Impedance 20MΩ// 2PF*x10, x100, x1000 Attenuator*To Ground MAX. Voltage: 4KV CAT III*Output Impedance 50Ω
-
product
Differential Probe
DP-02VF
*150MHz High Frequency*MAX. Input Voltage:*±40V DC or 80V p-p or AC 28V rms*Bandwidth: DC-150MHz*Input Impedance 1MΩ // 7.5PF*X2, X20 Attenuator*To Ground MAX. Voltage: 40V*Output Impedance 50Ω
-
product
Differential Probe
DP-16VF
*MAX. Input Voltage: ±8KV DC or 16KV p-p or AC 5.6KV rms*Bandwidth: DC-150MHz*Input Impedance 20MΩ // 5PF*X400, X4000 Attenuator*To Ground MAX. Voltage: 3.5KV CAT III*Output Impedance 50Ω
-
product
Differential Probe
DP-50
*This is the first detachable design (patent for 15 years)*4 range attenuation selection, easy for operation.*For big power using. Max. Measuring is 7KVp-p.I*t is capable for any brand of digital and analog oscilloscopes.*16MΩ high input impedance.
-
product
Differential Probe
DP-35
*High Sensitivity, High Voltage Model .*35MHz/1600 Vp-p Max.*Input Impedance 8MΩ//2.5PF*x10, x100 Attenuator, Easy to Convert.*Separating Design(Standard No.114205) Convenient & Durable.
-
product
Differential Probes < 1.5GHz
Differential active probes are like two probes in one. Instead of measuring a test point in relation to a ground point (like single-ended active probes), differential probes measure the difference in voltage of a test point in relation to another test point
-
product
Differential Pressure Probes
PP473-S…
Differential pressure probes complete with SICRAM module to measure pressure in the range 10, …, 2000 mbar.
-
product
Differential Voltage Probes
DP150/DP200pro
The DP differential isolation probes are an important accessory for any laboratory involved in power electronics and high voltage systems. These probes allow isolated and floating measurements with any oscilloscope or data recorder, whilst the oscilloscope can remain grounded. Using a DP150 or DP200pro probe, differential and floating measurements can be made on a variety of ac power systems like 230V/110V ac input power supplies, chopped and switching power supplies, thyristor controllers, variable speed motor drives (PWM signals), motor inrush current and measurement across current shunts. The isolated input is made via two 4mm/banana safety sockets. The BNC output allows easy connection to an oscilloscope. The DP probes can be powered from a 9V battery or external power supply.
-
product
Active Differential Probe
DF-600
The DF-600 Differential Active Probe is a high input impedance and low input capacitance probe. It also supports extremely high frequency bandwidth, and high voltage input. It is designed using three OP amps, namely two FET buffer OP amps and a low offset OP amp. Therefore, even with long-term operations, the measured voltage will not drift. The voltage offset always approach 0 volts. (USB power supply should be 5V ±2%). The following diagram shows the circuit of DF-600.
-
product
Differential Probes (4-6 GHz)
Differential active probes are like two probes in one. Instead of measuring a test point in relation to a ground point (like single-ended active probes), differential probes measure the difference in voltage of a test point in relation to another test point. Dx10/Dx20/Dx00A-AT 4-6 GHz differential probes are a general purpose probing solution with high input dynamic range and offset.
-
product
High Voltage Differential Probes
A high voltage differential probe is used for measuring the voltage difference between two test points where neither test point is at ground. High voltage differential probes from Tektronix can be used for signals up to 6000 V. These probes are the best choice for making non-ground referenced, floating or isolated measurements in large part due to their common mode rejection capability. These products are designed, manufactured, and serviced by Tektronix.
-
product
Differential Probes (8-30 GHz)
The DH series of 8 to 30 GHz active differential probes provides high input dynamic range, large offset capability, low loading and excellent signal fidelity with a range of connection options.
-
product
High Voltage Differential Probes
DP Series
Shenzhen Micsig Instruments Co., Ltd.
*Micsig DP Series High Voltage Differential Probes can be used with any brand of oscilloscope. *It adopts high-impedance isolation between the input and output to protect personal safety, converts the input high-voltage signal to a low-voltage signal for observation and analysis on oscilloscope.
-
product
High Voltage Differential Probes
High voltage differential probes provide high CMRR over a broad frequency range (up to 400 MHz) to simplify the measurement challenges found in noisy, high common-mode power electronics environments. The probe’s design is easy-to-use and enables safe, precise high voltage floating measurements.
-
product
High Voltage Differential Probe
ADF25A
Permits conventional grounded oscilloscopes to be used for the display and measurement of multiple floating signals with high common mode voltages
-
product
High Voltage Differential Probe
DP750-100
Shenzhen Micsig Instruments Co., Ltd.
*The leads and probe are with shielded design, interface ends are integrated in a compact box, no need to twist the cables, leads to a lower noise floor and has less interference. *Support one-press Zero calibration and automatic overrange alarm.*Directly powered by Micsig UPI interface, realise auto scaling setup, can also powered by oscilloscope via USB cable.
-
product
Differential Probe / Paired ProbeTOP
*1 Measured at 23°C environment connected to PS-02/PS-03 power supply(optional)*2 Broadband Noise, Bandwidth 30 MHz*3 Referred of output*4 Must be met to achieve best performance and avoid Damage to the Probe*5 Parts#890-880-104 : Twinholder M6 and 890-880-112 : Pair of Rail Clip Connectors 4mm are optional.
-
product
High-Voltage Differential Probe, 200 MHz
N2805A
The N2805A is a 200-MHz differential probe designed to provide superior differential signal measurements with long cable length (5 m), making it ideal in an environment where extended cable length is required. The probe offers 50:1 attenuation ratio, allowing it to be used adequately for up to ±100V DC+peakAC of high voltage differential measurements with high CMRR. The differential probe has a differential input resistance of 4 MΩ and low input capacitance of 4 pF to minimize circuit loading. The probe is powered by Keysight’s oscilloscope AutoProbe interface.