32-CH Discrete Output Module
HSL-DO32-M-N/HSL-DO32-M-P - ADLINK Technology Inc. (ADLINK)
Slave ID consumption: 2 consecutive from odd
"N" type for NPN sinking type output
Switch capacity: Single channel 500 mA; all channels 60 mA at 24VDC
Photo couple isolation voltage: 2500 Vrms
Response time: ON→OFF: 180µs, OFF→ON :1.2µs
LED indicator: Power, Link and Output status
Power supply: +10V to +30 VDC
Operating temperature: 0 to 60°C