Cytec Corp.

Cytec Corp manufactures over 300 types of innovative modular switching products that can be assembled and configured to provide an almost infinite variety of systems. We have 40 years experience with a large number of standard products to fill any switching need from the most basic automated test to advanced custom systems used in the aerospace industry and defense contractors. Don't see what you need or know where to start? Call us or e-mail and we can help!

  • (800) 346-3117
    585-381-4740
  • 585-381-0475
  • 2555 Baird Rd.
    Penfield, NY 14526
    United States

Filter Results By:

Products

Applications

Showing recent results 1 - 15 of 63 products found.

  • Analog or Digital Communications Switching Systems with D type Connectors

    RS Series - Cytec Corp.

    The RS Series computer controlled switching systems are designed to switch multi-wire groups of signal up to 25 wires. These systems are typically used for signals such as parallel TTL, RS232, RS422, WAN or modems, but can also be used for any group of analog or digital signals having a bandpass up to 30 MHz or a data rate up to 20 Mbps. A modular design concept is used that provides configuration flexibility by allowing display modules, different control modules and switch modules to be combined into a single chassis.

  • Chassis

    HXV/96-MF - Cytec Corp.

    These Chassis controls up to 12 8x1 modules, 12 4x2 modules, or up to 6 of the 8K modules in almost any combination or configuration. LEDs on the front panel show switch and power status. Add Switch Modules, Driver Modules and a Control Module to complete the system.

  • Chassis

    CXM/64-MF - Cytec Corp.

    These Chassis controls up to 8 8x1 modules, 16 4x1 modules or mixtures of 8x1"s, 4x1"s, 2x1"s and 2x2 modules in any combination or configuration for up to 64 relay drives. LEDs on the front panel show switch and power status. Add Switch Modules, display / driver modules and a Control Module to complete the system or simply buy the chassis wired out to D connectors to control your own relays. A manual control is optional.

  • Chassis

    CXAR/32-MF - Cytec Corp.

    These Chassis controls up to 4 8x1 modules, 8 4x1 modules or mixtures of 8x1"s, 4x1"s, 2x1"s and 2x2 modules in any combination or configuration. LEDs on the front panel show switch and power status. Add Switch Modules and a Control Module to complete the system. A pushbutton manual control is optional.

  • Chassis

    CXAR/128-MF - Cytec Corp.

    These Chassis controls up to 16 8x1 modules, 32 4x1 modules or any combination or configuration. LEDs on the front panel show switch and power status. Add Switch Modules, Driver Modules and a Control Module to complete the system.

  • Chassis

    CXM/32-MF - Cytec Corp.

    These Chassis controls up to 4 8x1 modules, 8 4x1 modules or mixtures of 8x1"s, 4x1"s, 2x1"s and 2x2 modules in any combination or configuration for up to 32 relay drives. LEDs on the front panel show switch and power status. Add Switch Modules and a Control Module to complete the system or simply buy the chassis wired out to D connectors to control your own relays. A pushbutton manual control is optional.

  • Chassis

    CXG Matrix - Cytec Corp.

    These Chassis are built as 50 or 75 ohm matrix configurations of 4x8 or 8x8 using tree switch configuration switch modules for high bandpass. The internal matrix block is wired out to BNC, SMA or other 50 or 75 ohm connectors. LEDs on the front panel show switch and power status. Add a Control Module to complete the system.

  • Chassis

    CXAR/64-MF - Cytec Corp.

    These Chassis controls up to 16 4x1 modules, or mixtures of 4x1"s, 2x1"s and 2x2 modules in any combination or configuration. LEDs on the front panel show switch and power status. Add Switch Modules, Driver Modules and a Control Module to complete the system.

  • Chassis

    JX/256-MF - Cytec Corp.

    These Chassis control up to 16 modules with as many as 32 two pole relays per module allowing 1xN multiplexers up to 1020x1, 2 pole muxes up to 512x1 or 2xN matrix configurations up to 256x2. Jumpering option allow the modules to be controlled as separate smaller muxes, i.e. 64 4x1 2 pole muxes, or combine specific groups to allow an almost unlimited combination of sizes. Add a Control Module and optional manual control to complete the system.

  • Chassis

    CXM/256-MF - Cytec Corp.

    These Chassis are typically used to control relays greater than 8x1 or control multiple relays in series forming larger switches than normally possible such as 16x1 to 32x1 sections. Or control mixtures of 8x1"s, 4x1"s, 2x1"s and 2x2 modules in any combination or configuration for up to 256 relay drives. LEDs on the front panel show switch and power status. Add Switch Modules, display / driver modules and a Control Module to complete the system or simply buy the chassis wired out to D connectors to control your own relays. A manual control is optional.

  • Chassis

    CXB/128-MF - Cytec Corp.

    These Chassis controls up to 16 switch modules in 16x8, 32x4 or dual 16x4 configurations. Available as single pole systems with the outer conductor of the BNC taken to ground, or isolated 2 pole systems switching both center conductor and ground. LEDs on the front panel show switch and power status. Add Switch Modules, Driver Modules and a Control Module to complete the system.

  • Chassis

    HXV/128-MF - Cytec Corp.

    These Chassis controls up to 16 8x1 modules, 16 4x2 modules, or up to 8 of the 8K modules in almost any combination or configuration. LEDs on the front panel show switch and power status. Add Switch Modules, Driver Modules and a Control Module to complete the system.

  • Chassis

    CXM/128-MF - Cytec Corp.

    These Chassis controls up to 16 8x1 modules, 32 4x1 modules or mixtures of 8x1"s, 4x1"s, 2x1"s and 2x2 modules in any combination or configuration for up to 128 relay drives. LEDs on the front panel show switch and power status. Add Switch Modules, display / driver modules and a Control Module to complete the system or simply buy the chassis wired out to D connectors to control your own relays. A manual control is optional. Chassis is available with sink or source relay drivers from + 5 to + 28 volts, ot TTL drivers for programmable attenuators. Firmware commands for Fade and Handover for WiFi, Cell Phone and WiMax labs. Fully custom systems built with little to no NRE.

  • Chassis

    HXV/32-MF - Cytec Corp.

    These Chassis controls up to 4 8x1 modules, 4 4x2 modules, or up to 2 of the 8K modules in almost any combination or configuration. LEDs on the front panel show switch and power status. Add Switch Modules, Driver Modules and a Control Module to complete the system.

  • Chassis

    RS/16 - Cytec Corp.

    These Chassis controls up to 16 switch modules with 9 to 25 wires switched per module. They are basically used to make a 9 to 25 wire 1x16 mux with D9, D15 or D25 connectors. LEDs on the front panel show switch and power status. Add up to 16 Switch Modules and a Control Module to complete the system. Push button manual control on the front panel is optional.

Get Help