Alpha Moisture Systems
AM Systems manufacture dewpoint meters, hygrometers and moisture analyzers trace moisture measurement in gases and dry compressed air, ranging from +20ºC to -110ºC dewpoint, ie 23,000 ppm down to 1 ppb. Products include Intrinsically Safe Portable Dewpoint Analyzers, Single Channel and Multi Channel Dewpoint Analysers and 4-20mA Loop Powered Dewpoint Transmitters.
- +44 1274 733 100
- +44 1274 733 200
- info@amsystems.co.uk
- 96 City Road
Bradford, West-Yorks BD8 8ES
United Kingdom
Filter Results By:
Products
Applications
-
product
Dewpoint Transmitters
Incorporated into the design of these transmitters are advanced electronics allowing for a power supply varying from 18 to 30V DC and are configured to output a linear, isolated, 4-20mA signal for the chosen range.
-
product
Sampling Systems
Alpha Moisture Systems' range of sampling systems have been developed through many years of experience in industrial moisture analysis. All systems are built using the highest quality components to ensure long term performance and reliability even in the toughest of applications.
-
product
Single Channel Analyzers
Alpha Moisture Systems' range of single channel moisture analysers have been developed to meet the requirements of all applications, requiring on-line analysis at a single sample point. These instruments combine robust construction and advanced electronics to ensure that they will provide accurate moisture analysis through a long and reliable service life.Unless stated otherwise, all on-line analysers are used in conjunction with any of our range of dedicated Ultra High Capacitance moisture sensors covering an overall range from -110ºC to +20ºC dewpoint, 0.001 to 23,000 ppm(v). Please contact us for further information.
-
product
Portable Analyzers
The key to the operation of Alpha Moisture Systems' Portable Analysers is the unique Desiccant Dry-Down Chamber. By keeping the sensor dry between tests, the special assembly of the head ensures that the instrument is always ready for immediate use. The head assembly consists of two chambers which have a telescopic action. When the head assembly is in the 'closed' or 'Dry-Down' position, the sensor is completely surrounded by desiccant, which absorbs the remaining water moisture from the sensor and hence it is dry and ready for use. The small space at the bottom of the test chamber enables the sample pipe to be purged before the test commences without wetting the sensor. By placing a finger over the outlet of the head, the sample pressure is able to open the test chamber automatically, exposing the sensor to the gas being tested and enabling accurate reading of moisture content in the sample gas. After each test the head assembly is closed by depressing the inner section so that the sensor will again be dried by the desiccant, leaving the sensor ready for use time and time again. The desiccant is kept in the inner chamber and is not exposed to ambient room air or the sample gas, therefore there is no need for frequent regeneration or replacement of the desiccant.
-
product
Chilled Mirror Hygrometers
Model CMH-RPC Chilled Mirror Hygrometer utilises a 3-stage Peltier cooler combined with an integral refrigeration unit to measure the water dewpoint (Td) in gases from below -90ºC to +20ºC (-130ºF to +68ºF)This primary measurement technique makes Model CMH-RPC the ideal instrument for laboratory, scientific and research applications, being especially suited as a reference instrument for checking and calibration of process and portable hygrometers.